2OM-1088-002.pdf - 第202页
Tg0699-PM-D2 1.3 "GUIDE" Window 0207-001 Chapter 2 1-7 *1 *4 *2 *3 *5 1.3 "GUIDE" Window • • • • • Window Layout When the [GUIDE] button is pressed in the "ERROR" window , the following wind…

Tg0699-PM-D2
1.2 "PRGM. CHECK" Window
0207-001 Chapter 2 1-6
*1
*4
*2
*3
*5
1.2 "PRGM. CHECK" Window
••
••
• Window Layout
When you select "Pattern Program Data Error" in the field under
"ITEM" in the "MAC. ERR." window and press the [PRGM.
CHECK] button, the following window opens.
When an item other than "Pattern Program Data Error" is
selected and the [PRGM. CHECK] button is pressed, noth-
ing appears in the display field.
Fig. 4A3
• Window Composition
*1 DATA
Displayed is the name of abnormal data.
*2 CONTENT
Displayed are the contents of an error.
*3 VALUE
Displayed is the value of abnormal data.
*4 [RESET] Button
Pressing this button cancels an alarm (sound) and closes the "ER-
ROR" window.
*5 [BUZZER RESET] Button
Pressing this button cancels an alarm (sound) only.

Tg0699-PM-D2
1.3 "GUIDE" Window
0207-001 Chapter 2 1-7
*1
*4
*2
*3
*5
1.3 "GUIDE" Window
••
••
• Window Layout
When the [GUIDE] button is pressed in the "ERROR" window, the
following window opens.
Fig. 4A4
••
••
• Window Composition
*1 LEVEL
Displayed are the levels (priority) of starting guidance mes-
sages.
*2 ITEM
Displayed are the starting guidance items.
*3 GUIDANCE
Displayed are the starting guidance messages.
*4 [RESET] Button
Pressing this button cancels an alarm (sound) and closes the
"ERROR" window.
*5 [BUZZER RESET] Button
Pressing this button cancels an alarm (sound) only.

Tg0699-PM-D2
1.4 "MAINT. STOP" Window
0207-001 Chapter 2 1-8
*1
*4
*2
*3
*5
1.4 "MAINT. STOP" Window
••
••
• Window Layout
When the [MAINT. STOP] button is pressed in the "ERROR"
window, the following window opens.
Fig. 4A5
••
••
• Window Composition
*1 DATE
Displayed are the date and time when the machine has stopped
for maintenance.
*2 ITEM
Displayed are the items related to the maintenance stops.
*3 CONTENT
Displayed are the contents of maintenance stops.
*4 [RESET] Button
Pressing this button cancels an alarm (sound) and closes the
"ERROR" window.
*5 [BUZZER RESET] Button
Pressing this button cancels an alarm (sound) only.