Error ID Item Description
0302000 Table
θθ
θθ
θ Origin Detect lost pulse error.
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1) Check for any obstacle around the table θ axis and then perform the
zeroing operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
0303000 Table
θθ
θθ
θ Limit (+)Limit error has been detected.
0304000 Table
θθ
θθ
θ Limit (-)Limit error has been detected.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor is defective.
(Cause 3) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero Table θ again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
0305000 Table
θθ
θθ
θ Servo Driver alarm signal was detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
0308000 Table
θθ
θθ
θ Servo Driver Over-Heat
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.