Error ID Item Description
0609000 P.E.C. Recognition Operation was incompleted, within specified time.
Camera X Servo
(Cause 1) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
0610000 P.E.C. Recognition Table-Z Axis is not at origin.
Camera X Interlock
(Cause 1) The table Z axis origin sensor (BPH171) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The P.E.C. recognition X axis was activated after the table Z axis had moved
up. (during the manual operation)
(Remedy 1) Check how the sensor is working in “Device Check” window (submenu).
When the sensor is not working, it is required to replace the sensor with
a new one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine
again. After that, restart the operation. When the same error still occurs,
contact our service personnel for details.
(Remedy 3) Perform the zeroing operation and re-start the operation.
0611000 P.E.C. Recognition P.C.B. stopper was down.
Camera X Interlock
(Cause 1) The P.E.C. recognition X axis is moved during the P.C.B. stopper is moved
down.
(Cause 2) The P.C.B. stopper upper limit (BPS070) is defective.
(Remedy 1) Move up the P.C.B. stopper and re-start the operation.
(Remedy 2) Check how the sensor is working in “Device Check” window (submenu).
If this operation does not reset the machine to its normal condition, it is
required to replace the sensor with a new one. Contact our service per-
sonnel for details.