Tg0699-PM-D2 2.3 Error IDs and Remedial Procedures 0207-001 Chapter 2 2-54 T able 4B52 Error ID Item Description 1018000 T able Chute Width The data was detected outside of the possible range. Data (Cause 1) Self-Diagnos…

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-53
Table 4B51
Error ID Item Description
1014000 Table Chute Width P.C.B. stopper was down.
Interlock
(Cause 1) The table chute width axis was activated after the P.C.B. stopper had moved
down.
(Cause 2) The P.C.B. stopper upper limit sensor (BPS070) is defective.
(Remedy 1) Move up the P.C.B. stopper and re-start the operation.
(Remedy 2) Check how the sensor is working in "Device Check" window (submenu).
If this operation does not reset the machine to its normal condition, it is
required to replace the sensor with a new one. Contact our service per-
sonnel for details.
1015000 Table Chute Width Table-Z Axis is not at origin.
Interlock
(Cause 1) The table Z axis origin sensor (BPH171) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The table chute width axis was activated after the table Z axis had moved
up. (during the manual operation)
(Remedy 1) Check how the sensor is working in "Device Check" window (submenu).
When the sensor is not working, it is required to replace the sensor with
a new one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine
again. After that, restart the operation. When the same error still occurs,
contact our service personnel for details.
(Remedy 3) Perform the zeroing operation and re-start the operation.
1016000 Table Chute Width Detected interference to support pin or JIG.
Interlock
(Cause 1) A wrong jig is attached or a support pin is attached to a wrong position.
(Cause 2) A wrong parameter is set in the "Y" text box of "P.C.B. Size" in the "Pattern
Program" window.
(Cause 3) The width error detection sensor (BPH051) is defective.
(Remedy 1) Check the location of the jig or the support pins and re-start the opera-
tion.
(Remedy 2) Check the contents of the pattern program and re-start the operation.
(Remedy 3) Check how the sensor is working in "Device Check" window (submenu).
When the same error occurs after the re-start operation, it is required to
replace the sensor with a new one.
Contact our service personnel for details.

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-54
Table 4B52
Error ID Item Description
1018000 Table Chute Width The data was detected outside of the possible range.
Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If the machine is not reset to its normal condition, shut down the power of
the machine once and power up the machine again. After that, re-start
the operation.
When the same error still occurs, contact our service personnel for de-
tails.
1019000 Table Chute Width Zeroing Opn. Not Complete
Origin
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-55