2OM-1088-002.pdf - 第262页

Tg0699-PM-D2 2.3 Error IDs and Remedial Procedures 0207-001 Chapter 2 2-57 T able 4B55 Error ID Item Description 1 109000 Input Conveyor Operation was incompleted, within specified time. Width Driver (Cause 1) The driver…

100%1 / 491
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-56
Table 4B54
Error ID Item Description
1101000 Input Conveyor Zeroing opn. was incompleted, within specified time.
Width Origin
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor is defective.
(Cause 3) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Wipe off the dirt on the sensor and zero the origin of the input conveyor
width axis again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
1102000 Input Conveyor Detect lost pulse error.
Width Origin
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1) Check for any obstacle around the input conveyor width axis and perform
the zeroing operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
1105000 Input Conveyor Driver alarm signal was detected.
Width Driver
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
1108000 Input Conveyor Driver Over-Heat
Width Driver
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-57
Table 4B55
Error ID Item Description
1109000 Input Conveyor Operation was incompleted, within specified time.
Width Driver
(Cause 1) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.
1111000 Input Conveyor PCB was exist on conveyor.
Width Interlock
(Cause 1) No operation is possible because a P.C.B. still exists on the conveyor.
(Cause 2) The P.C.B. detection sensors (BPH040 and BPH041) are defective.
(Remedy 1) Remove the P.C.B. and re-start the operation.
(Remedy 2) Check how the sensors are working in "Device Check" window (submenu).
When the sensors are not working, it is required to replace the sensors
with new ones.
Contact our service personnel for details.
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-58
Table 4B56