2OM-1088-002.pdf - 第265页
Tg0699-PM-D2 2.3 Error IDs and Remedial Procedures 0207-001 Chapter 2 2-60 T able 4B58 Error ID Item Description 1205000 Output Conveyor Driver alarm signal was detected. Width Driver (Cause 1) Self-Diagnostics Error Mes…

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-59
Table 4B57

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-60
Table 4B58
Error ID Item Description
1205000 Output Conveyor Driver alarm signal was detected.
Width Driver
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
1208000 Output Conveyor Driver Over-Heat
Width Driver
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If this operation does not reset the machine to its normal condition, con-
tact our service personnel for details.
1209000 Output Conveyor Operation was incompleted, within specified time.
Width Driver
(Cause 1) The driver is malfunctioning or an error has occurred during communication
with the host CPU.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, perform the zeroing operation.
If this operation does not reset the machine to its normal condition, the
driver may be defective. Contact our service personnel for details.

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-61
Table 4B59
Error ID Item Description
1211000 Output Conveyor PCB was exist on conveyor.
Width Interlock
(Cause 1) No operation is possible because a P.C.B. still exists on the conveyor.
(Cause 2) The P.C.B. detection sensor (BPH044 and BPH045) are defective.
(Remedy 1) Remove the P.C.B. and re-start the operation.
(Remedy 2) Check how the sensors are working in "Device Check" window (submenu).
When the sensors are not working, it is required to replace the sensors
with new ones. Contact our service personnel for details.
1212000 Output Conveyor The data was detected outside of the possible range.
Width Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If the machine is not reset to its normal condition, shut down the power of
the machine once and power up the machine again. After that, re-start
the operation.
When the same error still occurs, contact our service personnel for de-
tails.