Tg0699-PM-D2 2.3 Error IDs and Remedial Procedures 0207-001 Chapter 2 2-74 T able 4B72 Error ID Item Description 1501000 Load Power [Emergency] button pressed. Shut-Off (Cause 1) An [EMERGENCY STOP] button was pressed. (…

100%1 / 491
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-73
Table 4B71
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-74
Table 4B72
Error ID Item Description
1501000 Load Power [Emergency] button pressed.
Shut-Off
(Cause 1) An [EMERGENCY STOP] button was pressed.
(Remedy 1) Unlock the [EMERGENCY STOP] button and hold down the [POWER
ON] button for more than 3 seconds. After that, press the [RESET] button
in the "ERROR" window.
1502000 Load Power The air pressure is too low.
Shut-Off
(Cause 1) The main air pressure had dropped below 0.4 MPa (the set value of the
pressure switch).
(Remedy 1) Adjust the pressure to the correct one.
1503000 Load Power The safety door is open.
Shut-Off
(Cause 1) The safety door was opened.
(Remedy 1) Close the safety door and hold down the [POWER ON] button for more
than 3 seconds. After that, press the [RESET] button on the touch screen.
Power up the machine again and re-start the operation.
1504000 Load Power Detected circuit breaker off.
Shut-Off
(Cause 1) The circuit breaker of Q100, Q202, Q203 or Q204 is turned OFF.
(Remedy 1) Contact our service personnel for details.
1505000 Load Power Detected all load power monitor off.
Shut-Off
(Cause 1) The load power supply monitor (K021) is turned OFF.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.
If possible, check how the fuse (F001), K14, K15, K16, KM100, and KM200
are working.
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-75
Table 4B73
Error ID Item Description
1506000 Load Power Detected load power monitor off.
Shut-Off
(Cause 1) All load power supply monitor (K22) is turned OFF.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.
If possible, check how the fuse (F001), K14, K15, K16, KM100, and KM200
are working.
1601000 Control P.C.B. System error
1602000 Control P.C.B. Control board error
(Cause 1) An error has occurred in the SDS communication.
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.
1603000 Sensor Paste detect sensor error
(Cause 1) The paste height detection sensor (BPH064) is not adjusted correctly.
(Remedy 1) Contact our service personnel for details.
1604000 System Error Undefined Error
1605000 System Error Illegal error code
1606000 System Error Internal data error
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.