2OM-1088-002.pdf - 第285页
Tg0699-PM-D2 2.3 Error IDs and Remedial Procedures 0207-001 Chapter 2 2-80 T able 4B78 1701000 Squeegee Life Front squeegee exceeded life limit. (Cause 1) The frequency of the front squeegee use has exceeded the limitati…

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-79
Table 4B77

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-80
Table 4B78
1701000 Squeegee Life Front squeegee exceeded life limit.
(Cause 1) The frequency of the front squeegee use has exceeded the limitation.
(Remedy 1) Change the front squeegee and select the "Printed" data field of the re-
placed squeegee in the "Auto Stop Info" tab sheet. After that, press the
[Counter Clear] button.
1702000 Squeegee Life Rear squeegee exceeded life limit.
(Cause 1) The frequency of the rear squeegee use has exceeded the limitation.
(Remedy 1) Change the rear squeegee and select the "Printed" data field of the re-
placed squeegee in the "Auto Stop Info" tab sheet. After that, press the
[Counter Clear] button.
1801000 Fiducial Mark #1
1801001 Fiducial Mark #1 [Camera ID] exceeds the range of setting.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If the machine is not reset to its normal condition, shut down the power of
the machine once and power up the machine again. After that, re-start
the operation.
When the same error still occurs, contact our service personnel for de-
tails.

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-81
Table 4B79
Error ID Item Description
1801003 Fiducial Mark #1 [Camera Gain] exceeds the range of setting.
1801004 Fiducial Mark #1 [Camera Level] exceeds the range of setting.
1801011 Fiducial Mark #1 [Mark Size D1] exceeds the range of setting.
1801012 Fiducial Mark #1 [Mark Size D2] exceeds the range of setting.
1801014 Fiducial Mark #1 [Mark Judge Level] exceeds the range of setting.
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.