2OM-1088-002.pdf - 第290页

Tg0699-PM-D2 2.3 Error IDs and Remedial Procedures 0207-001 Chapter 2 2-85 T able 4B83 Error ID Item Description 1804000 P .E.C. Recognition T est 1804001 P .E.C. Recognition [Camera ID] exceeds the range of setting. T e…

100%1 / 491
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-84
Table 4B82
Error ID Item Description
1802029 Fiducial Mark #2 Image around fiducial mark was unstable.
1802030 Fiducial Mark #2 Error of mark figure similitude was extensive.
1802031 Fiducial Mark #2 Error of mark similitude or mark size was extensive.
1802032 Fiducial Mark #2 Specified mark was not found in window of recog.monitor.
(Cause 1) The fiducial marks do not conform to the coordinates X and Y of the fiducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Refer to Error ID 1801032 for details.
1802038 Fiducial Mark #2 Unavailable fiducial mark polality was set.
1802040 Fiducial Mark #2 Unavailable fiducial mark area was set.
1802043 Fiducial Mark #2 Recognition system error.
1802056 Fiducial Mark #2 Recog. transaction time over.
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-85
Table 4B83
Error ID Item Description
1804000 P.E.C. Recognition
Test
1804001 P.E.C. Recognition [Camera ID] exceeds the range of setting.
Test
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If the machine is not reset to its normal condition, shut down the power of
the machine once and power up the machine again. After that, re-start
the operation.
When the same error still occurs, contact our service personnel for de-
tails.
1804003 P.E.C. Recognition [Camera Gain] exceeds the range of setting.
Test
1804004 P.E.C. Recognition [Camera Level] exceeds the range of setting.
Test
1804011 P.E.C. Recognition [Mark Size D1] exceeds the range of setting.
Test
1804012 P.E.C. Recognition [Mark Size D2] exceeds the range of setting.
Test
1804014 P.E.C. Recognition [Mark Judge Level] exceeds the range of setting.
Test
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1804029 P.E.C. Recognition Image around fiducial mark was unstable.
Test
1804030 P.E.C. Recognition Error of mark figure similitude was extensive.
Test
1804031 P.E.C. Recognition Error of mark similitude or mark size was extensive.
Test
1804032 P.E.C. Recognition Specified mark was not found in window of recog.monitor.
Test
(Cause 1) The fiducial marks do not conform to the coordinates X and Y of the fiducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Refer to Error ID 1801032 for details.
Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-86
Table 4B84
Error ID Item Description
1804038 P.E.C. Recognition Unavailable fiducial mark polality was set.
Test
1804040 P.E.C. Recognition Unavailable fiducial mark area was set.
Test
1804043 P.E.C. Recognition Recognition system error.
Test
1804056 P.E.C. Recognition Recog. transaction time over.
Test
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.