Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-96
Table 4B94
Error ID Item Description
1904000
Screen Recognition
Test
1904001
Screen Recognition
[Camera ID] exceeds the range of setting.
Test
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If the machine is not reset to its normal condition, shut down the power of
the machine once and power up the machine again. After that, re-start
the operation.
When the same error still occurs, contact our service personnel for de-
tails.
1904003
Screen Recognition
[Camera Gain] exceeds the range of setting.
Test
1904004
Screen Recognition
[Camera Level] exceeds the range of setting.
Test
1904011
Screen Recognition
[Mark Size D1] exceeds the range of setting.
Test
1904012
Screen Recognition
[Mark Size D2] exceeds the range of setting.
Test
1904014
Screen Recognition
[Mark Judge Level] exceeds the range of setting.
Test
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1904029
Screen Recognition
Image around fiducial mark was unstable.
Test
1904030
Screen Recognition
Error of mark figure similitude was extensive.
Test
1904031
Screen Recognition
Error of mark similitude or mark size was extensive.
Test
1904032
Screen Recognition
Specified mark was not found in window of recog.monitor.
Test
(Cause 1) The fiducial marks do not conform to the coordinates X and Y of the fiducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Refer to Error ID 1901032 for details.

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-97
Table 4B95
Error ID Item Description
1904038
Screen Recognition
Unavailable fiducial mark polality was set.
Test
1904040
Screen Recognition
Unavailable fiducial mark area was set.
Test
1904043
Screen Recognition
Recognition system error.
Test
1904056
Screen Recognition
Recog. transaction time over.
Test
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Shut down the power of the machine once and power up the machine
again. After that, restart the operation.
When the same error still occurs, contact our service personnel for de-
tails.

Tg0699-PM-D2
2.3 Error IDs and Remedial Procedures
0207-001 Chapter 2 2-98
Table 4B96
Error ID Item Description
1906000
Screen Recognition
Camera
1906001
Screen Recognition
[Camera ID] exceeds the range of setting.
Camera
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
If the machine is not reset to its normal condition, shut down the power of
the machine once and power up the machine again. After that, re-start
the operation.
When the same error still occurs, contact our service personnel for de-
tails.
1906003
Screen Recognition
[Camera Gain] exceeds the range of setting.
Camera
1906004
Screen Recognition
[Camera Level] exceeds the range of setting.
Camera
1906011
Screen Recognition
[Mark Size D1] exceeds the range of setting.
Camera
1906012
Screen Recognition
[Mark Size D2] exceeds the range of setting.
Camera
1906014
Screen Recognition
[Mark Judge Level] exceeds the range of setting.
Camera
(Cause 1) The data has exceeded the allowable range.
(Remedy 1) Set correct parameters.
1906029
Screen Recognition
Image around fiducial mark was unstable.
Camera
1906030
Screen Recognition
Error of mark figure similitude was extensive.
Camera
1906031
Screen Recognition
Error of mark similitude or mark size was extensive.
Camera
1906032
Screen Recognition
Specified mark was not found in window of recog.monitor.
Camera
(Cause 1) The fiducial marks do not conform to the coordinates X and Y of the fiducial
marks or the recognition mark data in the pattern program.
(Remedy 1) Refer to Error ID 1901032 for details.