2OM-1088-002.pdf - 第78页

Tg0699-PM-D2 (6) Level Set the threshold levels of the fiducial marks. High : Both identity and similarity between the shape of a fidu-cial mark and the real image are detected on a high level. Middle : Either identity o…

100%1 / 491
Tg0699-PM-D2
(3) Size D1 and Size D2
Set the dimensions of fiducial marks.
Unit : mm
Refer to "Type and Size" in "(8) Fiducial Marks" for details.
(4) Rcg. Area
Set the recognition areas for the P.E.C. and screen recognition
functions.
Unit : mm
Set preferably small values to avoid false recognition and
shorten recognition time.
0207-001 Chapter 1 2-18
1.2 Operation Data
Recognition Area
(Complete Square)
Mark Dimension
Rcg. Area
05.0
Fig.3B43
Size D1
Size D2
0.50
0.00
Fig.3B42
Fig. 3B44
(5) Pol.
Set polarities of the mark patterns for images captured by the
cam-era.
Select either mode according to the difference in contrast
between a mark pattern and its surrounds to get a clear fidu-
cial image.
Bright : Bright Fiducial/Dark Background
Dark : Dark Fiducial/Bright Background
Wrong mode selection causes malfunction of fiducial
mark recognition.
Pol.
Bright
Fig.3B45
Tg0699-PM-D2
(6) Level
Set the threshold levels of the fiducial marks.
High : Both identity and similarity between the shape of a
fidu-cial mark and the real image are detected on a
high level.
Middle : Either identity or similarity between the shape of a
fidu-cial mark and the real image are detected on a
middle level.
Low : Both identity and similarity between the shape of a
fidu-cial mark and the real image are detected on a
low level.
Identity :
Identity between the shapes of the specified mark and
the real image (including the size)
Similarity :
Similarity between the shapes of the specified mark
and the real image
(7) Lighting
A lighting mode can be specified to illuminate the P.C.B.
Only “Normal” can be selected for the standard machine
(standard specifications).
Normal
Select this when there is enough difference in contrast be-
tween a fiducial mark and a P.C.B. (Recognition by Pattern
Matching Method)
0207-001 Chapter 1 2-19
1.2 Operation Data
P.C.B.
Fiducial Mark
(Bright)
Level
High
Fig.3B46
Lighting
Normal
Fig.3B47
Fig. 3B48
Tg0699-PM-D2
0207-001 Chapter 1 2-20
1.2 Operation Data
(8) Fiducial Marks
P.E.C. Fiducial Marks
Material
Copper Leaf (Au and Ni plating possible but mirror surfaces cannot be
used.)
Solder-Plated Marks (Consult our marketing department for details.)
Solder Leveler (Consult our marketing department for details.)
Type and Size
Table 3B2