2OM-1088-002.pdf - 第86页

Tg0699-PM-D2 1.2.9 Cleaning (1) Cleaning Area Set offset values as a cleaning area based on the end plane of the P .C.B. in the Y direction. Unit : mm The default values are "-010 mm" for "Origin" and…

100%1 / 491
Tg0699-PM-D2
(6) Paste Detect
Set the number of P.C.B.’s to be produced by the time when
the subsequent detection is made after the amount of remain-
ing solder paste is once detected.
When "0" is set, this function becomes invalid.
Unit : pieces
Data Input Range: 0 to 99
This parameter becomes valid only when "Paste
Detect" is selected in the "Paste Supply Interval
Mode" text box (described in (4)).
Paste Detect
00
Fig.3B60
0207-001 Chapter 1 2-26
1.2 Operation Data
Tg0699-PM-D2
1.2.9 Cleaning
(1) Cleaning Area
Set offset values as a cleaning area based on the end plane of
the P.C.B. in the Y direction.
Unit : mm
The default values are "-010 mm" for "Origin" and
"+000 mm" for "Depth". A wide area will be cleaned in
both directions (10 mm on one side) based on the Y
direction of the P.C.B.
(2) Cleaning Interval
Set the number of P.C.B.’s to be printed as a cycle for auto-
matic cleaning.
Every time the number of printed P.C.B.’s reaches the speci-
fied one (cycle), the machine automatically performs a clean-
ing operation once.
(3) Option Mode
1 (For.), 2 (Back), 3 (For.), 4 (Back)
Select a wiping mode based on the number of each screen
movement.
NO WIPE : The underside of the screen is not wiped
DRY : Solvent is not discharged and the underside of
the screen is wiped with cleaning paper. (Dry
Paper)
WET : The underside of the screen is woped with
cleaning paper while solvent is being dis-
charged. (Wet Paper)
VAC.+DRY : The underside of the screen is wiped with dry
paper while the solder paste on the underside is
being sucked.
VAC.+WET : The underside of the screen is wiped with wet
pa-per while the solder paste on the underside
is being sucked.
(4) Cleaning Speed
Set the speed at which the screen should be moved for auto-
matic cleaning of the underside.
Unit : mm/sec
Data Input Range: 10 to 100
Cleaning Speed [mm/sec]
050
Fig.3B64
1 (For.)
2 (Back)
VAC.+DRY
VAC.+WET
3 (For.)
WET
Fig.3B63
4 (Back)
WET
Cleaning Interval
00
Fig.3B62
Origin
Depth
-010
+010
Fig.3B61
0207-001 Chapter 1 2-27
1.2 Operation Data
Tg0699-PM-D2
(5) Paper Feed Pitch
Set the pitch at which the cleaning paper should be fed for
cleaning of the underside.
Unit : mm
Data Input Range: 0 to 45
(6) Solv. Dispense Time
Set the solvent dispensing time for wet-type cleaning.
Unit : seconds
Data Input Range: 0.1 to 2.0
Paper Feed Pitch [mm]
20
Fig.3B65
Solv. Dispense Time [sec]
1.0
Fig.3B66
0207-001 Chapter 1 2-28
1.2 Operation Data