00198442-04_UM_TX-V2_EN - 第109页
Instruction manual SIPLACE TX 3 Technical data and assemblies From software version 714.0 12/2020 3.2 Ambient conditions and connection values 109 3.2.3 Compressed air supply and compressed air sp ecification 3 Compresse…

3 Technical data and assemblies Instruction manual SIPLACE TX
3.2 Ambient conditions and connection values From software version 714.0 12/2020
108
3.1.6 Component supply
3.2 Ambient conditions and connection values
3.2.1 Ambient conditions for packaging, transportation and storage
3
3.2.2 Environmental conditions for operation
3
Component supply Tracks occupied
SIPLACE TX
With C&P20 P2
With CPP
With CPP /TH
With CPP or TwinHead and JTF-ML at location 1
38 feeder modules, each with 8mm X
40 feeder modules, each with 8 mm X
40 feeder modules, each with 8 mm X
28 feeder modules, each with 8 mm X
SIPLACE TX2 / TX2i m / TX2i m 4 mm
With C&P20 M3
With CPP M
38 feeder modules, each with 8mm X
40 feeder modules, each with 8 mm X
Technical data
Tape reel diameter to 330.2 mm (13")
Component trolley changeover time < 1 minute
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature
SIPLACE TX
Between 15°C and 35°C
Atmospheric humidity 30% to 75%
(on average not higher than 45%, so that there is no risk of
condensation on the placement machine.)
Ambient pressure > 750 mbar (corresponds to 1700 m above mean sea level)

Instruction manual SIPLACE TX 3 Technical data and assemblies
From software version 714.0 12/2020 3.2 Ambient conditions and connection values
109
3.2.3 Compressed air supply and compressed air specification
3
Compressed air supply
Compressed air pressure val-
ues
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connection 1/2" hose connection
Compressed air consumption
*a
Placement head configuration Compressed air con-
sumption with vac-
uum pump
*b
Compressed air con-
sumption without vac-
uum pump
*c
SIPLACE TX2i/TX2 C&P20 P2/C&P20 P2
CPP / CPP
CPP / TH
120 Nl/min
No option
No option
No option
260 Nl/min
220 Nl/min
SIPLACE TX2i m / TX2i m and
TX2i m 4mm
C&P20 M3/C&P20 M3
CPP M/CPP M
C&P20 M3/ / CPP M
120 Nl/min
No option
190 Nl/min
No option
260 Nl/min
190 Nl/min
SIPLACE TX1 C&P20 P2
CPP
TH
70 Nl/min
No option
No option
No option
130 Nl/min
130 Nl/min
Compressed air specification according to ISO 8573
Particle size (ISO class 3) 5 µm
Particle density (ISO class 3) 5 mg/m³
Maximum oil content (ISO class 1) Particle density 0.01 mg/m³
Pressure dewpoint (ISO class 4) Dewpoint + 3°
*)a Average consumption values.Under normal atmospheric conditions at 20°C and 1013 hPa.
*)b Vacuum pump only for the SIPLACE SpeedStar.
*)c Optional
Important notes
When setting up a placement machine (TX, SX or X-Series S) next to a SIPLACE TX, observe the correct spacing between them. In these
cases, use suitable conveyor extensions to create room of 0.5m for the operator between the two machines.
To achieve top placement performance, fit the first machine in a SIPLACE TX line with an input conveyor extension and the last placement
machine in the line with an output conveyor extension.

3 Technical data and assemblies Instruction manual SIPLACE TX
3.2 Ambient conditions and connection values From software version 714.0 12/2020
110
3.2.4 Electrical ratings and energy consumption
3
PLEASE NOTE
Use of a residual current protection device
The low ground leakage current of the system makes it possible to use an upstream re-
sidual current protection device at the customer end. This must be all-current sensitive
(RCD type B).
Electrical ratings
Supply voltage Fuse
Main power supply 3/N/PE ~ 380 V / 220 V to 415 V / 240 V ± 10 %; 50/60 Hz
3/N/PE ~ 200 V / 115 V to 220 V / 127 V ± 10 %; 50/60 Hz
*a
3/PE ~ 200 V to 220 V ± 10 %; 50/60 Hz
a
Mains power connec-
tion
Without cable
Cable 5 x 2.5 mm² WITH CEE plug, red 16 A (in accordance with IEC 60309) (3 x 380 V~
to 3 x 415 V~)
Cable 5 x 2.5 mm² WITHOUT plug (3 x 200 V~ to 3 x 220 V) or
(3 x 380 V~ to 3 x 415 V~
Full load current 3.8 A - 3.3 A / phase
*b
6.3 A - 5.8 A / phase
b
6.3 A - 5.8 A / phase
b
3 x 16A characteristic C
*c
3 x 15 A characteristic C
c
3 x 15 A characteristic C
c
Short circuit classification of machine (SCCR)
*d
10 kA
Energy consumption
With a vacuum pump
*e
Without a vacuum pump
Average apparent power 2.6 kVA 2.3 kVA
Average effective power 2.0 kW 1.2 kW
*)a With options package
*)b Selection of customer's supply voltage range.
*)c For example: Siemens circuit breakers in accordance with UL 489 and IEC (order no.: 5SJ4 316-7HG42)
or
EATON Industries circuit breaker FAZ-C16/3-NA 16A 3p (UL 489, CSA C22.2 no. 5, IEC 60947-2)
*)d With the original mains connection cable. The marked short circuit rating (SCCR) relates to the beginning of the original
mains cable. In the case of customer modifications, the factory-set length of the mains cable to the machine may not
be shortened nor the factory-set conductor cross-section increased, as this would have a negative impact on the short
circuit rating (SCCR).
*)e Vacuum pump only for the SIPLACE SpeedStar.