00198442-04_UM_TX-V2_EN - 第111页
Instruction manual SIPLACE TX 3 Technical data and assemblies From software version 714.0 12/2020 3.3 Dimensions and weight 111 3.3 Dimensions and weight 3.3.1 T echnical data - dimensions and weight 3 Length *a Without …

3 Technical data and assemblies Instruction manual SIPLACE TX
3.2 Ambient conditions and connection values From software version 714.0 12/2020
110
3.2.4 Electrical ratings and energy consumption
3
PLEASE NOTE
Use of a residual current protection device
The low ground leakage current of the system makes it possible to use an upstream re-
sidual current protection device at the customer end. This must be all-current sensitive
(RCD type B).
Electrical ratings
Supply voltage Fuse
Main power supply 3/N/PE ~ 380 V / 220 V to 415 V / 240 V ± 10 %; 50/60 Hz
3/N/PE ~ 200 V / 115 V to 220 V / 127 V ± 10 %; 50/60 Hz
*a
3/PE ~ 200 V to 220 V ± 10 %; 50/60 Hz
a
Mains power connec-
tion
Without cable
Cable 5 x 2.5 mm² WITH CEE plug, red 16 A (in accordance with IEC 60309) (3 x 380 V~
to 3 x 415 V~)
Cable 5 x 2.5 mm² WITHOUT plug (3 x 200 V~ to 3 x 220 V) or
(3 x 380 V~ to 3 x 415 V~
Full load current 3.8 A - 3.3 A / phase
*b
6.3 A - 5.8 A / phase
b
6.3 A - 5.8 A / phase
b
3 x 16A characteristic C
*c
3 x 15 A characteristic C
c
3 x 15 A characteristic C
c
Short circuit classification of machine (SCCR)
*d
10 kA
Energy consumption
With a vacuum pump
*e
Without a vacuum pump
Average apparent power 2.6 kVA 2.3 kVA
Average effective power 2.0 kW 1.2 kW
*)a With options package
*)b Selection of customer's supply voltage range.
*)c For example: Siemens circuit breakers in accordance with UL 489 and IEC (order no.: 5SJ4 316-7HG42)
or
EATON Industries circuit breaker FAZ-C16/3-NA 16A 3p (UL 489, CSA C22.2 no. 5, IEC 60947-2)
*)d With the original mains connection cable. The marked short circuit rating (SCCR) relates to the beginning of the original
mains cable. In the case of customer modifications, the factory-set length of the mains cable to the machine may not
be shortened nor the factory-set conductor cross-section increased, as this would have a negative impact on the short
circuit rating (SCCR).
*)e Vacuum pump only for the SIPLACE SpeedStar.

Instruction manual SIPLACE TX 3 Technical data and assemblies
From software version 714.0 12/2020 3.3 Dimensions and weight
111
3.3 Dimensions and weight
3.3.1 Technical data - dimensions and weight
3
Length
*a
Without conveyor extension and with hand guard
With input conveyor extension
*b
With output conveyor extension
With input and output conveyor extension)
1000 mm
1260 mm
1604 mm
1864 mm
Width
Outer contour of machine protection (both tables "inside")
With monitor
Outer contour of machine protection (table location 1 "outside")
With monitor
2232 mm
2420 mm
2347 mm
2441mm
Height of machine (for PCB conveyor height 950 mm)
Machine protection closed
With 2-color indicator lamp
With 3-color indicator lamp
Without indicator lamp (height of packaging)
With folded-up short protective cover 45 degrees position
With folded-up short protective cover 60 degrees position
With folded-up short protective cover 45 degrees position
With folded-up short protective cover 60 degrees position
1500 mm
1690 mm
1735 mm
1500 mm
1960 mm
2070 mm
2050 mm
2175 mm
Floor clearance of placement machine TX1/TX2
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
120 mm ± 15 mm
150 mm ± 15 mm
170 mm ± 15 mm
Machine floor clearance TX2i
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
120 mm ± 13 mm
150 mm ± 13 mm
170 mm ± 13 mm
Weight
SIPLACE TX (without feeder modules)
SIPLACE TX (fully equipped with feeder modules)
2036 kg
2150 kg
Location
*c
With table on outside
2.23 m²
2.33 m²
Even floor surface load (without feeder module)
Even floor surface load(with feeder modules)
Characteristic surface load
6.46 kN/m²
6.79 kN/m²
7.70 kN/m²
Number of machine feet 4
Max. noise emissions 75 dB (A)
*)a Measured at the outer contour of the machine protection.
*)b Only at the first machine in the line.
*)c Measured at the outer contour of the machine protection and without conveyor extension.

3 Technical data and assemblies Instruction manual SIPLACE TX
3.3 Dimensions and weight From software version 714.0 12/2020
112
3.3.1.1 Overview of dimensions
3
Fig. 3.3 - 1 Overview of dimensions - example SIPLACE TX2
Example:
(1) Length = 1000 mm
(2) Width = 2232 mm
(3) Height =
1735 mm