00198442-04_UM_TX-V2_EN - 第192页
4 Setting up and commissioning In struction manual SIPLACE TX 4.4 Infrastructure at the installation location From software ve rsion 714.0 12/2020 192 4.4.4 Overview of the microfuses 4 Fig. 4.4 - 7 Overview of the micro…

Instruction manual SIPLACE TX 4 Setting up and commissioning
From software version 714.0 12/2020 4.4 Infrastructure at the installation location
191
4.4.3.6 Mains connection - mains connection cable WITHOUT plug (configuration 3)
The placement machine is supplied with an approx. 5m mains connection cable WITHOUT plug.
4
4
Fig. 4.4 - 6 Description of wires in the mains power cable
WARNING
The mains connection cable may only be connected by a qualified electrician.
The mains connection cable may only be connected by a qualified electrician.
The regulations of the country in which the placement machine is operated apply.
1 = (L1): three-phase
2 = (L2): three-phase
3 = (L3): three-phase
4 = (N): neutral conductor
green/yellow = (PE): conductor

4 Setting up and commissioning Instruction manual SIPLACE TX
4.4 Infrastructure at the installation location From software version 714.0 12/2020
192
4.4.4 Overview of the microfuses
4
Fig. 4.4 - 7 Overview of the microfuses
4
Fuse Components Electricity Voltage [V]
F1 Shuttle 6.3 AT 42
F3 Shuttle & Option 6.3 AT 24
F4 Distributor 4.0 AT 24
F5 Monitor 1&2 /CIN 6.3 AT 24
F6 MGCU Supply 6.3 AT 42
F7 Conveyor control 6.3 AT 24
F10 Internal Polyfuse 24

Instruction manual SIPLACE TX 4 Setting up and commissioning
From software version 714.0 12/2020 4.4 Infrastructure at the installation location
193
F11 CSB signal 6.3 AT 24
F12 CSB supply 6.3 AT 24
F13 Diagnostic Supply 3.0 (SMD) 24
F14 Gantry/Head 1 6.3 AT 42/24
F15 Gantry/Head 2 6.3 AT 42/24
F16 Conveyor drives 10.0 AT 42
F19 Gantry 1 6.3 AT 160
F20 Gantry 2 6.3 AT 160
F21 Vision (not used) 6.3 AT 42
F31 FCU 1 16 AC
(external)
27,5
F32 FCU 2 16 AC
(external)
27,5
F33 Station PC 10 AC
(external)
27,5
Fuse Components Electricity Voltage [V]