00198442-04_UM_TX-V2_EN - 第211页
Instruction manual SIPLACE TX 4 Setting up and commissioning From software version 714.0 12/2020 4.6 Adjusting the comp onent t rolley to the PCB conveyor heig ht 211 4.6 Adjusting the component trolley to the PCB convey…

4 Setting up and commissioning Instruction manual SIPLACE TX
4.5 Setting up the placement machine From software version 714.0 12/2020
210
4.5.8 Placement machine foot clearances and the stationary PCB conveyor edges
4.5.8.1 Placement machine foot clearances
4
Fig. 4.5 - 9 Placement machine foot clearances in millimeters

Instruction manual SIPLACE TX 4 Setting up and commissioning
From software version 714.0 12/2020 4.6 Adjusting the component trolley to the PCB conveyor height
211
4.6 Adjusting the component trolley to the PCB conveyor
height
The component trolley can be easily and quickly adjusted to the following PCB conveyor heights:
900 mm 4
930 mm (standard height) 4
950 mm 4
4
Fig. 4.6 - 1 Component trolley
(1) Holes for the transport heights of 900, 930 and 950 mm.
(2) Changeover table
900 mm
930 mm
950 mm
(1)
(2)

4 Setting up and commissioning Instruction manual SIPLACE TX
4.6 Adjusting the component trolley to the PCB conveyor height From software version 714.0 12/2020
212
4.6.1 Warning instructions
4
4.6.2 Tools and equipment
You will need the following tools and equipment to adjust the height of the component trolley:
– Fit-up aid (item no. 03015976-xx)
– Lifting device for raising the component trolley table, carrying capacity at least 80 kg
4.6.3 Changing the component trolley height
4
Fix the fit-up aid to the changeover table with the two M8 x 50 hexagon socket head screws.
Hook the leverage device into the eyelet.
Loosen the fixture pin and lift the changeover table into the required position.
Insert the fixture pin into the hole for the required height.
Dismantle the fit-up aid.
WARNING
Adjustment of component trolley height by certified persons!
Only ASM Assembly Systems GmbH&Co.KG engineers or qualified personnel are per-
mitted to adjust the component trolley height.
Always follow the applicable accident prevention regulations.
Remove all the feeder modules from the changeover table, if you want to adjust the
height of the changeover table.
WARNING
Risk of damage!
Lifting and lowering the changeover table can lead to deformation of it.
Remove all the feeder modules from the changeover table.
Fit the fit-up aid to the changeover table in order to adjust the height.