00198442-04_UM_TX-V2_EN - 第277页
Instruction manual SIPLACE TX 6 Station exte nsions From software version 714.0 12/2020 6.1 Nozzle changer 277 6.1.2.4 Nozzle magazine with 9 garages for 28xx nozzles 6 Fig. 6.1 - 7 Nozzle m agazine for 28xx nozzles (1) …

6 Station extensions Instruction manual SIPLACE TX
6.1 Nozzle changer From software version 714.0 12/2020
276
6.1.2.3 Nozzle magazine with 20 garages for 20xx nozzles
6
Fig. 6.1 - 6 Nozzle magazine for 20xx nozzles with 20 garages - locking plate open
(1) 20 garages for 20xx nozzles
(2) Fiducials (only visible when locking plate open)
(2)
(1)
(2)

Instruction manual SIPLACE TX 6 Station extensions
From software version 714.0 12/2020 6.1 Nozzle changer
277
6.1.2.4 Nozzle magazine with 9 garages for 28xx nozzles
6
Fig. 6.1 - 7 Nozzle magazine for 28xx nozzles
(1) 5 garages for 28xx nozzles with a maximum nozzle length of 12.5 mm
(garage numbers 1, 5, 6, 8 and 9)
(2) 4 garages for 28xx nozzles with a maximum nozzle length of 16.5 mm
(garage numbers 2, 3, , 4 and 7)
(3) Fiducials (only visible when locking plate open)
(1)
(2)
(3)
(3)

6 Station extensions Instruction manual SIPLACE TX
6.1 Nozzle changer From software version 714.0 12/2020
278
6.1.2.5 Technical data
6
Nozzle changer for the SIPLACE MultiStar
Number of magazines per location
*a
SIPLACE TX1/ TX2 / TX2 m 6
SIPLACE TX2i 6
4
3
Max. number of nozzle garages per location
SIPLACE TX1 / TX2 / TX2 m 6
SIPLACE TX2i 6
80
60
Standard configuration per location
SIPLACE TX1 / TX2 / TX2 m 6
6
6
SIPLACE TX2i 6
3 magazines with 60 x 20xx nozzle garages
1 magazine with 9 x 28xx nozzle garages
2 magazines with 40 x 20xx nozzle garages
1 magazine with 9 x 28xx nozzle garages
Nozzle types 20xx, 28xx
*)a All magazines in the nozzle changer must be configured.