Instruction manual SIPLACE TX 6 Station exte nsions From software version 714.0 12/2020 6.6 Stationary cameras 297 6.6.2 St ationary component camera P&P , type 33 GigE Item no. 00588100-xx St ationary c amera for th…

100%1 / 330
6 Station extensions Instruction manual SIPLACE TX
6.6 Stationary cameras From software version 714.0 12/2020
296
6.6.1.2 Technical data
6
Component dimensions 0.2 mm x 0.2 mm up to 16 mm x 16 mm for single component
measurement
Component range 0402 to SO, PLCC, QFP, sockets, plugs, BGA, special components,
bare dies, flip-chips, shields
Min. lead pitch 0.25 mm
Min. lead width 0.1 mm
Min. ball pitch 0.14 mm
Min. ball diameter 0.08 mm
Field of vision 19.4 mm x 19.4 mm
Illumination type Front-illumination (6 levels, programmable as required)
Instruction manual SIPLACE TX 6 Station extensions
From software version 714.0 12/2020 6.6 Stationary cameras
297
6.6.2 Stationary component camera P&P, type 33 GigE
Item no. 00588100-xx Stationary camera for the CPP head, type 33 GigE
6
Fig. 6.6 - 2 Design of stationary component camera P&P, type 33 GigE
(1) Camera housing with integral camera and camera amplifier
(2) Glass plate - illumination and lens levels below
6 Station extensions Instruction manual SIPLACE TX
6.7 IPC-Hermes-9852 From software version 714.0 12/2020
298
6.6.2.1 Safety instructions
6
6.6.2.2 Technical data
6
6.7 IPC-Hermes-9852
IPC-HERMES-9852 is a communication protocol for SMT lines and can replace the IPC SMEMA
interface. This protocol allows you to transfer more information than previously via the IPC
SMEMA interface.
This could be, for example:
Unique board IDs
Barcodes
Conveyor speed,
Board length and width
Board thickness
Transport clearance height
Weight
All this information can be transmitted along the whole line without interruption.
For a detailed description, see the Administrator Manual IPC-HERMES-9852, item no.
[00198615-xx].
WARNING
Risk of collisions!
When changing the placement head from a TwinStar/VHF to a SpeedStar, the SpeedStar
collides with the camera housing.
Dismantle the stationary component camera for the TwinStar.
When changing the placement head from a TwinStar to a MultiStar CPP, the station-
ary component camera is fitted in the bottom position.
Component dimensions 0.5 mm x 0.5 mm to 55 mm x 45 mm
Component range 0402, MELF, SO, PLCC, QFP, electrolytic capacitors, BGA
Min. lead pitch 0.3 mm
Min. lead width 0.15 mm
Min. ball pitch 0.35 mm
Min. ball diameter 0.2 mm
Field of vision 65 mm x 50 mm
Illumination type Front-illumination (6 levels, programmable as required)