00198442-04_UM_TX-V2_EN - 第304页
7 Maintenance Instruction manual SIPLACE TX 7.1 Safety instructions for maintenance work From software version 714.0 12/2020 304

Instruction manual SIPLACE TX 7 Maintenance
From software version 714.0 12/2020 7.1 Safety instructions for maintenance work
303
7
7
7
7.1.1 Safety instructions for hazardous substances
7
CAUTION
Cleaning and lubrication
Do not use any solvents for cleaning, use only ethanol!
Alternatively, you can also use isopropanol – IPA.
Cleaning with compressed air inside the placement machine or module assemblies
is expressly prohibited.
CAUTION
Risk of cutting at IC and FC camera
The edges of the mirror could cut your fingers.
Protect yourself by wearing laboratory gloves and avoid touching the edges.
Laboratory gloves are also a prerequisite for effective cleaning (fingerprints!).
CAUTION
Only one person may be in the area of the location at any one time.
The reason for this is to ensure the safety of the operating personnel or of a second per-
son. The two-hand operation of the component trolley insert only enables one person to
be reliably protected from danger.
CAUTION
Observe the safety data sheets
When handling hazardous substances, (e.g. Loctite 241, ethanol) observe the ap-
plicable safety data sheet.
7 Maintenance Instruction manual SIPLACE TX
7.1 Safety instructions for maintenance work From software version 714.0 12/2020
304

Instruction manual SIPLACE TX 8 Annex
From software version 714.0 12/2020 8.1 EC Declaration of Conformity
305
8Annex
8.1 EC Declaration of Conformity
The product described below:
8
8
Manufactured by
ASM Assembly Systems GmbH&Co.KG
Rupert-Mayer-Str. 44
81379 Munich 8
conforms to the regulations and standards listed in the EC Declaration of
Conformity provided.
Product
Placement machine
Type SIPLACE TX1 SIPLACE TX2 SIPLACE TX2i
Item no.: 588301 588302 588300
Type SIPLACE TX2 m SIPLACE TX2i m SIPLACE TX2i m 4 mm
Item no.: 588520 588525 588526