00198442-04_UM_TX-V2_EN - 第71页
Instruction manual SIPLACE TX 2 Operational safety From software version 714.0 12/2020 2.3 Classification of camera systems 71 2.3 Classification of camera systems 2.3.1 Classification of placement machin e 2 2.3.1.1 Las…

2 Operational safety Instruction manual SIPLACE TX
2.2 Warning labels From software version 714.0 12/2020
70
2.2.14 Warning labels on the PCB conveyor
2
Fig. 2.2 - 18 Warning labels on the PCB conveyor
Item. W 004, on the laser light barrier
2.2.14.1 Warning label W 004
2
W 004 in fig. 2.2 - 18, page 70, item no. 03223713-01
(Quantity on the PCB conveyor: 2)
W 004
2
LASER RADIATION
Risk class 2
Acc. to IEC 60825-1:2014
Do not look into beam!

Instruction manual SIPLACE TX 2 Operational safety
From software version 714.0 12/2020 2.3 Classification of camera systems
71
2.3 Classification of camera systems
2.3.1 Classification of placement machine
2
2.3.1.1 Laser classification
The following modules are assigned to risk class 2:
2
The ready-for-operation placement machine is assigned to risk class 2.
The risk classes are determined according to IEC 60825-1:2014.
Assembly Data
Component sensor on SpeedStar Maximum optical output power: < 1 mW
Wavelength: 635 nm
Component sensor on MultiStar Maximum optical output power: < 1 mW
Wavelength: 635 nm
Laser light barrier on PCB conveyor Maximum optical output power: < 1 mW
Wavelength: 650 nm

2 Operational safety Instruction manual SIPLACE TX
2.3 Classification of camera systems From software version 714.0 12/2020
72
2.3.2 Classification of the camera systems
2.3.2.1 Camera types with bright LEDs - risk group 1
The bright LEDs are fitted in the following cameras. These are classified as risk group 1, according
to IEC 62741:.
– Component camera type 23, 30, 41 and 45
– Stationary component camera type 25 and 33
– PCB camera, type 54
2
2.3.2.2 Camera types with blue LEDs - risk group 2
The ultra-bright blue LEDs are fitted in the following cameras. These are classified as risk group
2, according to IEC 62741:.
– Component camera, type 48
2
2
PLEASE NOTE
Risk group 1
Do not look into the beam of the ready-for-operation camera!
2
Risk group 2
The beam from cameras with ultra-bright blue LEDs can be a haz-
ard.
Do not look into the beam of the ready-for-operation camera!