00192975-01 - 第89页

S-20/S-23HM/F4/F5/F 5HM/S-25HM/HS- 50 Conversion Instructions Power supply 03/2001 Edition 3 Converting the power supply on S-20/S-23HM/ S-25HM/F4/F5 and F5HM machines 89 3.6.1 Converting the transformer T1 from 230 V AC…

100%1 / 134
Power supply S-20/S-23HM/F4/F5/F5HM/S-25HM/HS-50 Conversion Instructions
3.6 Converting the changeover table from 230 VAC to 115 VAC 03/2001 Edition
88
3.5.7 Inserting plug-in adapter X1 into the service socket
Å Insert the USA plug-in adapter X1 into the service socket.
3.5.8 Carry out the safety check to DIN EN 60 204
Å When the conversion is complete, carry out a safety check to DIN EN 60 204.
Å Follow the procedure described in section 2, page 72 onwards.
3.6 Converting the changeover table from 230 VAC to 115 VAC
RISK OF DEATH 3
The changeover table must be uncoupled during the rewiring work. The power cable and
communication cable must both be unplugged. 3
Fig. 3 - 5 Changeover table, transformer T1
a 7UDQVIRUPHU7
s 7RSSDUWRIIUDPH
S-20/S-23HM/F4/F5/F5HM/S-25HM/HS-50 Conversion Instructions Power supply
03/2001 Edition 3 Converting the power supply on S-20/S-23HM/ S-25HM/F4/F5 and F5HM machines
89
3.6.1 Converting the transformer T1 from 230 VAC to 115 VAC
Transformer T1 (item 1 in Fig. 3 - 5) can be accessed from beneath the top part of the frame
(item 2 in Fig. 3 - 5
). 3
Å Loosen the four hexagon socket-head screws.
Å Pull the cover plate over the transformer housing down and off.
Fig. 3 - 6 Changeover table, transformer T1, terminals
Å Detach the black wire from terminal 5 and connect to terminal 4.
3.6.2 Replacing fuse F1
Å Replace the fuse in the fuse holder in the cover panel:
old rating: 3.15 A T
new rating: 6.3 A T
Voltage
Terminals
Blue wire Black wire
237 VAC 1 5
230 VAC 2 5
223 VAC 3 5
122 VAC 1 4
115 VAC 2 4
108 VAC 3 4
Tab. 3 - 3 Changeover table, supply voltages for transformer T1
Power supply S-20/S-23HM/F4/F5/F5HM/S-25HM/HS-50 Conversion Instructions
3.6 Converting the changeover table from 230 VAC to 115 VAC 03/2001 Edition
90
Å Replace the adhesive label specifying 3.15 A with the 6.3 A label from the conversion kit.
Å Replace the cover panel over the transformer and tighten the four hexagon socket-head
screws.
3.6.3 Carry out the safety check to DIN EN 60 204
Å When the conversion is complete, carry out a safety check to DIN EN 60 204.