Power supply S-20/S-23HM/F4/F5/F5HM/S-25HM/HS-50 Conversion Instructions
3.8 Converting placement machines from 3x208V~ to 3x400V~ 03/2001 Edition
98
3.8.6 4 or 5-wire connection for the power supply
The connections are produced using either 4 or 5 wires, according to the electricity companys
requirements. 3
4-wire connection 3
In the 4-wire connection, the neutral conductor (NE) and protective earth (PE) are combined to
form a single PEN wire. 3
Å Insert the yellow-green wires BR3 and BR4 between the N and PE terminals in the right-hand
terminal block on terminal strip X206 (see Fig. 3 - 12
).
5-wire connection 3
In the 5-wire connection, the neutral conductor (NE) and protective earth (PE) consist of separate
wires. 3
Å Remove the yellow-green wires BR3 and BR4 from between the N and PE terminals in the
right-hand terminal block on terminal strip X206 (see Fig. 3 - 12
).
Machine Terminal block
Terminal strip X206
Jumpers BR3 and BR4 between PE and N
4-wire connection 5-wire connection
S-20/F4/F5 00321510-xx Yes No
S-23HM/S-25HM/F5HM 00337342-xx Yes No
Tab. 3 - 4 Terminal blocks, right-hand side
S-20/S-23HM/F4/F5/F5HM/S-25HM/HS-50 Conversion Instructions Power supply
03/2001 Edition 3 Converting the power supply on S-20/S-23HM/ S-25HM/F4/F5 and F5HM machines
99
Fig. 3 - 12 Terminal block, right-hand side, terminal strip X206
3.8.7 Carry out the safety check to DIN EN 60 204
Å When the conversion is complete, carry out a safety check to DIN EN 60 204.
Å Follow the procedure described in section 2, page 72 onwards.
3
3
Power supply S-20/S-23HM/F4/F5/F5HM/S-25HM/HS-50 Conversion Instructions
3.9 Converting the changeover table from 115 VAC to 230 VAC 03/2001 Edition
100
3.9 Converting the changeover table from 115 VAC to 230 VAC
RISK OF DEATH 3
The changeover table must be uncoupled during the rewiring work. The power cable and
communication cable must both be unplugged. 3
Fig. 3 - 13 Changeover table, transformer T1
a 7UDQVIRUPHU7
s 7RSSDUWRIIUDPH
3
3.9.1 Converting transformer T1 from 115 VAC to 230 VAC
Transformer T1 (item 1 in Fig. 3 - 13) can be accessed from beneath the top part of the frame
(item 2 in Fig. 3 - 13
). 3
Å Loosen the four hexagon socket-head screws.