00191369-01 - 第206页

6 Vision functions User Manual HS-50 6.5 Teach Fiducial Software-V ersion 5.01 E dition 01/99 204 – Prog ram transf orm 5 Y ou can qui t the in put boxes with 2. , $ FFHSW or &DQFHO .  –C l i c k o n 2. or $FF HSW w…

100%1 / 442
User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.5 Teach Fiducial
203
NOTE
Section 3 includes a general description of
using the menus with trackball, touch screen and function keys F1 to F12.
the layout of the screen.
the screen displays.
 7HDFK)LGXFLDO
 7HDFK)LGXFLDO)ORZ&KDUW
The 7HDFKILGXFLDOflow chart shows in graphic form all menu options together with their sub-func-
tions. The menus are indicated by being bordered with a solid line, while the option boxes use a
dashed line and the input boxes a dotted line.
 ,QIRUPDWLRQRQWKH)ORZ&KDUW
 0HQXV
The 7HD FKILGXFLDO option includes the following menus:
Select fiducial
Teach fiducial
Contrast sensitivity
Test fiducial
The 6DYHILGXFLDOGDWD option box will be displayed each time you quit the 7HDFKI LGXFLDO option
after having created or modified fiducial data. You are thus given the choice of saving these fidu-
cial parameters or of discarding them.
You can quit the individual menus by clicking on either the icon of another menu or on the 0DLQ
YLHZicon.
 ,QSXW%R[HV2SWLRQ%R[HV
The system provides the following input boxes for entering data, for displaying values and for ex-
ecuting actions:
Define new fiducial
Change fiducial name
6 Vision functions User Manual HS-50
6.5 Teach Fiducial Software-Version 5.01 Edition 01/99
204
Program transform 5
You can quit the input boxes with 2., $FFHSW or &DQFHO.
–Click on 2. or $FFHSW with the mouse and the data will be transferred to the program and
saved. The input box closes.
Click on the &DQF HO button and the data will be discarded and the input box closed.
 %XWWRQV
For selecting options the system provides the following buttons:
6H OHFWWKHWHDFKLQJJDQWU\
Use the mouse to select the teaching gantry.
6DYHILGXFLDO
The fiducial parameters just generated will be saved when you click on this button.
/RDGILGXFLDO
Once you have selected the desired fiducial from the lists field, click on the /RDGILGXFLDO but-
ton. The fiducial parameters will be loaded.
 9LGHR,PDJHV
The camera image of the MVS system (vision analysis unit) can be displayed on the screen of the
station computer. In addition the screen will include header and footers:
The header includes, for example, the currently selected menu option, the fiducial number,
analysis criteria, measurement results and so on.
The footers include command sequences, keyboard commands, camera coordinates and so
on.
You can always quit displays of video images with the (6& key. The corresponding menu window
will then reappear.
 :DUQLQJDQG0HVVDJH%R[HV
Messages are text fields which contain information regarding actions, warnings and so on. They
will appear under the following circumstances:
incorrect operator actions (for example, a board still on the processing conveyor).
requests to the operator to carry out certain actions (for example, remove board).
instructions (for example, input the name of a fiducial).
indicates the system is busy performing an action (for example, loading fiducial data).
User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.5 Teach Fiducial
205
Main view
7HDFKILGXFLDOPHQXRSWLRQV
0DLQYLHZPHQX
Set-up
Error
Feeders
Gantry 3 functions
Gantry 4 functions
PCB transport 2
PCB transport 1
Teach fiducial
Test component
SITEST
GEM
Main view
Markenauswahl
Teach fiducial
Contrast graduation
Test fiducial
Save
fiducial
7HDFKILGXFLDO
PHQXRSWLRQ
Select fiducial
Fiducial
processed?
Fiducial is
restored
Fiducial
is saved
OK
Yes
Cancel
Gantry 1 functions
Gantry 2 functions