6 Vision functions User Manual HS-50
6.6 Test Component Software-Version 5.01 Edition 01/99
244
’Test component’ menu options
’LEAD’, ’GRID’, and ’BALL’ measure mode menus
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Measurement Window
Separately
for each pin
Combined
windows
Cancel Accept
Number of
balls to be
measured
Cancel Accept
Fast
Robust
Measurement Evaluation
Position
and
existance
Quality
Cancel Accept

User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.6 Test Component
245
6HO HFW3 DFNDJH)RUP0HQ X
If you select the 7HVW FRPSRQHQW option in the 0DLQ YLHZ menu, the following actions will occur:
– The functions for the vision system are activated in the station computer
– The 6HO HFWSDFNDJHIRUP menu will drop down.
– The station computer will determine the package form numbers list with commentaries from
the set-up.
Fig. 6.6 - 9 menu
The menu allows you to choose between the following options, as the diagram shows:
– Selection of the camera types (80F machines only).
– Load GF data
– Save GF data
NOTE
Buttons are active when the text on the button is black (rather than gray). This means that you can

6 Vision functions User Manual HS-50
6.6 Test Component Software-Version 5.01 Edition 01/99
246
launch the associated function by clicking on the button with the mouse.
The /RDG*)GDWDbuttonwill, for example, only be active if you have previously clicked on a pack-
age form in the lists field.
The 6DYH*)GDWDbutton will only be active if you have changed the package form parameters.
You can switch from the ’Test component ’ menu to the Main menu at any time in order to start
actions such as "Fill track" etc. The settings in the ’Teach fiducial’ menu will be retained, which
means that the same conditions will be set up when you return to the ’Test component’ menu.
However, if you have changed the fiducial data or taught a new fiducial, and then switch from the
Main menu to the ’Test component’, ’Single functions’, ’SITEST’ or ’Continue placement’ menu,
the ’Save fiducial data’ selection box will appear when you leave the ’Teach fiducial’ option. You
can then either save the modified or new data or delete it.
By selecting the 6DYH*)GDW Doption you cause the station computer to send the package form
data to the line computer, where it is saved. The modified package form data is updated in the
remaining stations as well. The transformation tables are held locally in the station computer.