00191369-01 - 第265页
User Manual HS-50 6 Vision functions Software-Version 5.01Edition 01/99 6.6 Test Component 263 Over lays: gray: Profile in the integrati on dire ction in questi on blue: Gr adie nts from the a bove p rofiles yellow…
6 Vision functions User Manual HS-50
6.6 Test Component Software-Version 5.01 Edition 01/99
262
Cross:
white: Results of position recognition -> x and y angles
brown: Residual angle tolerance for subsequent measurement steps
Overlay:
gray: Profile in the integration direction in question
blue: Gradients from the above profiles
yellow: Results from the geometric filter
red: Interpolation limits for position determination
light blue: Results of interpolation-> position
&RUQHU'ULYHQ0RGH
See Section 6.6.4.14 on page 6 - 281 for a definition of the measuring methods.
This measurement method can be recognized by the windows around the entire row of leads.
Procedure:
Å Determine the position in the direction of the leads in the light blue window
Å Determine the position vertically to this in the dark blue window
Å Calculate the position of each lead group and thus of the component
Rectangles:
light blue: Search window for the position in the direction of the leads
dark blue: Search window for the position vertically to this
green: x and y tolerances
Star:
orange: Results: Location of the group in question
Comments:
Depending on which measurement algorithm was selected the middle or the end of the lead
group in the direction of the leads will be shown.
Cross:
white: Results of position recognition -> x and y angles
User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.6 Test Component
263
Overlays:
gray: Profile in the integration direction in question
blue: Gradients from the above profiles
yellow: Results from the geometric filter
red: Interpolation limits for position determination
light blue: Results of interpolation -> Position
Comments:
The overlay will be provided for both the light blue and the dark blue search window.
/HDGGULYHQPRGH
See Section 6.6.4.14 on page 6 - 281 for a definition of the measuring methods.
This measurement method can be recognized by
– either there being a window around a leads group (combined window, preset value)
– or there being a window around every single lead (separate window). By entering the hex code
you can modify the window types VHSDUDWH or FRPELQHG ZLQGRZ in the 0HDVXUHPRGH
menu.
Procedure:
Each lead will be measured in a way similar to corner-driven mode or the entire leads group will
be measured.
Rectangles:
dark blue: search window around the entire leads group or around every
light blue: search window around the first lead in a group
green: x and y tolerances
Cross:
white: Results of position recognition -> x and y angles
Overlay:
gray: Profile in the integration direction in question
blue: Gradients from the above profiles
The gradients are only required and displayed for the profiles in the
direction of the leads.
yellow: Results from the geometric filter

6 Vision functions User Manual HS-50
6.6 Test Component Software-Version 5.01 Edition 01/99
264
red: Interpolation limits for position determination
light blue: Results of interpolation -> Position
Comments:
An overlay is available for both directions of interpolation.
2SWLFDOPHDVXUHPHQWRI%*$VDQGIOLSFKLSVZLWKWKH) RU) SODFHPHQWPDFKLQH
The crosshairs indicate the position of the component in the camera coordinates system. The
outline of the component will be emphasized by the use of color.
The measured values represent geometric component parameters such as
– position in the camera coordinates system
– rotation angle
– maximum offset of the balls in x and y directions
– factor for the quality of measurement
*ULGGULYHQPRGH
See Section 6.6.4.14 on page 6 - 281 for a definition of the measuring methods.
Grid-driven mode works with preset pattern tolerances and is therefore to be regarded as the first
measurement step in the optical surveying of BGAs and flip-chips. To ascertain the approximate
position it will be adequate to measure just a few connections.
The number of balls to be measured and the pattern tolerances define the size of the search win-
dow. The rough position and the skew of the component are determined in corners mode - in other
words, a search window size is defined for each corner of the component. This measurement
method can be identified by
– the synthetic model being shown in pixel resolution at the lefthand edge of the video image,
and
– the 4 windows at the corners of the component.
Procedure:
– The algorithm defines 4 dark blue corner windows on the basis of the pattern tolerances and
the balls defined in the package form file. The default search value is 5 balls.
– A detection algorithm runs with the aim of detecting all balls corresponding to this type. Those
found will be marked with light blue crosses.
– The balls defined in the package form file are determined by the search algorithm. The balls
found are marked with a white outline. If defined balls are not found an error message will ap-
pear on the screen.