User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.6 Test Component
291
 µ/HDG¶PHDVXULQJPRGH
Click on the ‘Setting’ field in the ‘Lead’ measuring mode to call up the /HDGPHDVXULQJPRGH
menu.
This menu is used to
specify the lead measuring method.
to select the windows separately for each lead or a combined window for every lead to be mea-
sured.
0HDVXUHPHQW
If the inner lead tips are mapped better than the outer tips, for example if a shiny lead is bent up-
wards slightly, you can select one of the following options:
measuring the tips via the inner tips of the leads, for bases, for example
center of the lead, center measurement, for PLCC, SOJ, for example
measuring the tips via the outer tips of the leads, for QFP, SOT, SO, for example
6 Vision functions User Manual HS-50
6.6 Test Component Software-Version 5.01 Edition 01/99
292
:LQGRZV
Separately for each lead
Here you define the window in the primary direction (dark blue) and secondary direction (light
blue) for measuring each lead for irregular components and special components.
&RPELQHGZLQGRZ
Used to define a common window for all the leads.
 µ*ULG¶PHDVXULQJPRGH
Click on the ‘Setting’ field in the ‘Grid’ measuring mode to call up the *ULGPHDVXULQJPRGH
menu.
In this menu, enter the number of balls to be measured at each corner.
User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.6 Test Component
293
 ¶%DOO¶ P HDVXULQJPRGH
Click on the ’Settings’ button in ’Ball’ measuring mode to call up the ’Ball measuring mode’ menu.
This menu can be used to
select the measuring methods listed under ’Measurement’ and
evaluate the position and presence of balls and carry out a quality analysis.
0HDVXUHPHQW
You can choose between the following measuring methods:
the profile method for fast analysis or
the filter method for a more robust measuring method, although this will take longer.
The ’fast’ measuring method is generally sufficient. However, we recommend the ’robust’ measur-
ing method if the quality is insufficient, for example if the quality factor is less than 50.