User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.6 Test Component
291
µ/HDG¶PHDVXULQJPRGH
Click on the ‘Setting’ field in the ‘Lead’ measuring mode to call up the /HDGPHDVXULQJPRGH
menu.
This menu is used to
– specify the lead measuring method.
– to select the windows separately for each lead or a combined window for every lead to be mea-
sured.
0HDVXUHPHQW
If the inner lead tips are mapped better than the outer tips, for example if a shiny lead is bent up-
wards slightly, you can select one of the following options:
– measuring the tips via the inner tips of the leads, for bases, for example
– center of the lead, center measurement, for PLCC, SOJ, for example
– measuring the tips via the outer tips of the leads, for QFP, SOT, SO, for example

6 Vision functions User Manual HS-50
6.6 Test Component Software-Version 5.01 Edition 01/99
292
:LQGRZV
–
Separately for each lead
Here you define the window in the primary direction (dark blue) and secondary direction (light
blue) for measuring each lead for irregular components and special components.
– &RPELQHGZLQGRZ
Used to define a common window for all the leads.
µ*ULG¶PHDVXULQJPRGH
Click on the ‘Setting’ field in the ‘Grid’ measuring mode to call up the *ULGPHDVXULQJPRGH
menu.
In this menu, enter the number of balls to be measured at each corner.

User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.6 Test Component
293
¶%DOO¶ P HDVXULQJPRGH
Click on the ’Settings’ button in ’Ball’ measuring mode to call up the ’Ball measuring mode’ menu.
This menu can be used to
– select the measuring methods listed under ’Measurement’ and
– evaluate the position and presence of balls and carry out a quality analysis.
0HDVXUHPHQW
You can choose between the following measuring methods:
– the profile method for fast analysis or
– the filter method for a more robust measuring method, although this will take longer.
The ’fast’ measuring method is generally sufficient. However, we recommend the ’robust’ measur-
ing method if the quality is insufficient, for example if the quality factor is less than 50.