10.2 Technical data for the feeder modules Software-Version 5.01 01/99 Issue
366
%XONFDVHIHHGHU
Item no. 00142318-xx
Width 30 mm
Tracks per module 2
Maximum number of modules 4 x 12
Magazine capacity Approx. 5000
Feeding rails 0603 / 0.45 mm high Item no. 00142321-xx
0603 / 0.80 mm high Item no. 00142322-xx
0805 / 0.45 mm high Item no. 00142323-xx
0805 / 0.60 mm high Item no. 00142324-xx
0805 / 0.85 mm high Item no. 00142325-xx
0805 / 1.25 mm high Item no. 00142326-xx
Minimelf Item no. 00142328-xx
Cycle time < 80 ms
Main power supply 30 VDC

User Manual HS-50 10 Component handling
Software-Version 5.0101/99 Issue 10.3 Setting up the feeder modules
367
6HWWLQJXSWKHIHHGHUPRGXOHV
3UHS DUL QJWKHFRPSRQHQWWDEOHDQGPRGXOHIRUVHWXS
Å Select the setting range for the feeder module to be used
(see Vibrator configuration).
Å Move the placement head to the waiting position and press the emergency stop button.
Å Open the protective covers.
Å Clean the contact surface for the feeder modules and the contact surface for the feeder mod-
ules on the component table.
Å Place the feeder module on the previously selected track on the component table (see Vibrator
configuration).
,QVHUWWKHPRGXOH
Å Insert the module so that the back of the module is held by the centering ball and the front is
fixed in place by the corresponding centering pin on the component table. Make sure that the
module is placed on the component table in the correct position for its width.
Å Check that the module is firmly seated on the component table.
Å Connect the module plug to the socket beneath the location.
PLEASE NOTE
When you connect the module, make sure that you use the right socket for the location since
the module receives the control pulse via this socket. The feeder module may not work cor-
rectly if it is not connected to the right socket.
Å Close the protective covers and switch the control on again.
Å Carry out a refill check if necessary.
Å Continue placement.

10 Component handling User Manual HS-50
10.4 Tape container Software-Version 5.01 01/99 Issue
368
.H\ WR )LJ
(1) Feeder module, 30 mm wide
(2) Feeder module, 45 mm wide
(3) Feeder module, 30 mm wide
7DSHFRQWDLQHU
2Y HUYLHZ
Reels up to 15" in diameter may be used, although for 15" reels you should use spindles as well.
Insert the spindles into the partitions as shown in Fig. 10.4 - 1.
PLEASE NOTE