00191369-01 - 第380页
10 Component handling User M anual HS-50 10.6 Component changeover tables Software-Version 5.01 01/99 Issue 378

User Manual HS-50 10 Component handling
Software-Version 5.0101/99 Issue 10.6 Component changeover tables
377
'RFNLQJWKHFRPSRQHQWFKDQJHRYHUW DEOH
WARNING
Check that the placement head is outside the range of the component changeover table.
CAUTION
When docking the component table, ensure that the table bed is in its top end position and the clip
(item 5) is folded up.
Å Carefully push the component changeover table into the placement system.
Å Plug the connecting cable for the component changeover table into the socket (item 2) in the
placement system.
Å Open the flap over the push-button for raising the component changeover table.
Å Hold down the button (item 1) until the component table bed reaches its top end position.
Å Check that the centering holes in the component table bed are exactly over the centering pins
on the placement system.
Å Then fold down the clip (item 5) of the component changeover table to lower the component
table bed.
Å Ensure that the centering pins engage in the centering holes in the component table bed and
that the component table bed is fully lowered.
Å Close the flap over the push-button (item 1).
Å Close the protective cover.
10 Component handling User Manual HS-50
10.6 Component changeover tables Software-Version 5.01 01/99 Issue
378

User Manual HS-50 11 Station extensions / options
Software Version 5.0101/99 Issue 11.1 HS-50 nozzle changer
379
6WDWLRQH[WHQVLRQVRSWLRQV
+6QR]]OH FKDQJHU
2YHUYLHZ
The placement system is supplied as standard with four revolver heads and four nozzle changers.
As an option, a second nozzle changer can be installed for each revolver head.
The nozzle changer consists of at least one, and up to five magazines, each with 12 nozzle gara-
ges (see Fig. 11.1 - 1). The magazines are seated on a common support and each magazine is
centered using two parallel pins and fixed in place with clips.
7HFKQLFDOGDWD
1R]]OHFKDQJHUIRUWKHUHYROYHUKHDG
Dimensions (length x width x height) 472.5 mm x 64 mm x 90 mm
Number of nozzle garages Min. 12 / max. 60
Nozzle types 7xx
Time required to open and close the locking plate < 200 ms
Pneumatic circuit Air line 5.3 bar