3&%GDWDWUDQVIHU
)XQFWLRQDOGHVFULSWLRQ
The ’Machine options’ menu contains a ’PCB data transfer’ option. The aim of this function is to
increase the placement system’s performance on the line. To do this, an entire PCB is measured
at the ILUVW placement station and the associated fiducial, single circuit, ink spot, etc. data is deter-
mined, saved and sent to the next station. At subsequent stations, the data is then determined for
two fiducial positions only. These two fiducial positions are then used to correct the position for the
PCB to be processed at each station. It is thus not necessary to measure the entire PCB again,
together with its single circuits, ink spots etc.
$FWLYDWLQJWKH¶3&%GDWDWUDQVIHU¶RSWLRQ
Å Click on the ’Machine options’ button in the basic view.
The ’Machine options’ window opens.

User Manual HS-50 11 Station extensions / options
Software Version 5.0101/99 Issue 11.5 PCB data transfer
395
Å In the ’Options’ box, check the ’PCB data transfer’ option for the station concerned.
Å Click on the ’OK’ button. The ’PCB data transfer’ option is now active.
PLEASE NOTE: The ’PCB data transfer’ option can only be used in conjunction with a PCB bar-
code reader.