00191369-01 - 第407页

User’s Manual SIPLACE HS-50 12 Station Extensions - Software Software Vers ion SR.501.xx E dition 01/99 12.2 GE M In terfac e 405  2SHUDWLRQ   6HWWLQJW KH&RQWU RO0 R GH The contr ol mode s pecifies h…

100%1 / 442
12 Station Extensions - Software User’s Manual SIPLACE HS-50
12.2 GEM Interface Software Version SR.501.xx Edition 01/99
404
The figure below presents the "Options" menu which is present in the menu bar of the user
interface. This menu contains the options for the GEM interface settings. 

0HQX2SWLRQVIRUWKH*(0,QWHUIDFH 
&RQWUROPRGH
This opens a dialog box which is used to set the control mode at the GEM computer.
*(0'HIDXOWV
This opens the window used to specify the default settings for the GEM interface.
&RQWUROVDQG,QGLFDWRUVLQWKH*(0,QWHUIDFH 


This button switches the user interface to "State view" mode. (Load placement program, send/
receive message) 

The current control mode is displayed in a separate area in the user interface’s information
bar. 

The icon displayed in the user interface’s status area (on the right-hand side) indicates the cur-
rent status of the connection to the GEM computer. 

User’s Manual SIPLACE HS-50 12 Station Extensions - Software
Software Version SR.501.xx Edition 01/99 12.2 GEM Interface
405
 2SHUDWLRQ
  6HWWLQJWKH&RQWURO0 RGH
The control mode specifies how the station is supplied with the necessary placement data. 
Å In the main view, select the 2SWLRQVmenu and then choose the &RQWUROPRGHoption.
Å The following selection box appears.
3RVVLEOH6HWWLQJV 
6WDQGDORQH 
(This control mode is used for test purposes only)
If a cluster is specified at the station, all necessary data will be loaded from the hard disk of
the station computer.
The data must be located on the station computer’s hard disk. 
*(0+RVW 
In this control mode only the host computer can specify the placement programs.
The data must be located on the host computers hard disk. 
NOTE
This setting must be activated if you wish to download placement programs from the GEM
computer to the station computer. See also section 12.2.2.6. 
/LQH&RPSXWHU 
If a cluster is specified at the station, all necessary data will be loaded from the line computer.
The data must be located on the line computer’s hard disk. 
6,3/$&(3UR 
This control mode cannot be set in the current software version. 

Å Select the button for the required control mode.
Å Click 2. to confirm and activate this setting.
12 Station Extensions - Software User’s Manual SIPLACE HS-50
12.2 GEM Interface Software Version SR.501.xx Edition 01/99
406
 'HILQLQJWKH*(0GHIDXOW6HW WLQJV
You use the "GEM default settings..." menu option to make various settings which will be used
at power-up as default parameters for the station. 
Å In the main view select the 2SWLRQVmenu and then select the option *(0GHIDX OWVHW
WLQJV. The following window is displayed.
