Retrofit instructions: New 1-wire wiring for the SIPLACE X-series 11/2005 Edition 43 2 Retrofit instructions: New 1-wire wiring for the SIPLACE X-series 2.1 Advant ages of the new wiring – The new wiring for the 1-wire b…

Nachrüstanleitung Neue 1-Wire-Verkabelung SIPLACE X-Serie
Ausgabe 11/2005
42
1.9.2.5 1-Wire-CAT5-TEMP neu (für den IGUS-Kabelschlepp zwingend erforderlich)
1
Abb. 1.9 - 18 1-Wire-CAT5-TEMP Platine neu
1
1.9.3 Abschließende Maßnahmen
1
Beachten Sie, daß, wenn man die Option PP- und BE-Abwurfbehälterabfrage einbaut, in der Sta-
tionssoftware ein fehlender Behälter nur dann angezeigt wird, wenn der Sicherheitskreis ge-
schlossen ist (d.h. alle Tische eingezogen und Hauben geschlossen) und die Starttaste gedrückt
wird. 1
1
: Kontrollieren Sie die Temperatursensoren, die Pipettenwechsler und die Abwurfbehälter.
(mehr Infos dazu im Student Guide FSE (Ausgabe 09/2005), Kapitel Communication).
1
1
1
Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
43
2 Retrofit instructions:
New 1-wire wiring for the SIPLACE
X-series
2.1 Advantages of the new wiring
– The new wiring for the 1-wire bus eliminates internal communication problems.
– The cable for the 1-wire bus is removed from the machine CAN bus cable in the vicinity of the
locations and is run in specially shielded cables.
– The quality of the 24V supply is also improved by a voltage regulator on the control board in
the nozzle changer.
2.2 Variants of the new wiring
There are two variants of the new wiring. If a part of the older variant (there are around 30 ma-
chines in the field) fails and has to be replaced, then the entire wiring must be converted to the
new variant. 2
The 24 V supply must be fitted for both variants. 2
2.3 One-wire bus
Introduction of the message loop into software version 505 (601) required the number of inputs
and outputs to be reduced or an additional I/O module to be installed. The "one-wire bus system"
was introduced to take account of the space available in the machine and on cost grounds.
The one-wire bus controls the nozzle changer in all 4 sectors, transfers the temperature values
from the sensors to the head plates and carries the gantry data.

Retrofit instructions: New 1-wire wiring for the SIPLACE X-series
11/2005 Edition
44
Tasks
(1) Controlling the nozzle changer, 6/12 C&P heads (1st and 2nd row)
(2) Controlling the nozzle changer, 20 C&P heads (1st and 2nd row), with magazine scan
(3) 2 temperature sensors are fixed to the head board for each gantry.
(4) The gantry identification is saved on an EEPROM.
(We distinguish between board gantry CFK 02, DTC gantry CFK 04 and gantry CFK 06. It
therefore follows that the machine database for the dynamic parameters of the main axes that
is loaded differs according to the type of gantry).
(5) Option: Scan of the reject bin in all 4 sectors
2.3.1 Structure of the 1-wire bus
As the name suggests, the data is transferred on one wire. The data is therefore sent to the sub-
system serially.
The 1-wire bus is used for non-time-critical sequences and can be implemented as a single master
bus with "any number" of slaves (stations).
2.3.1.1 Basic structure
The 1-wire bus essentially consists of a master with an EEPROM (control unit) that controls vari-
ous sub-modules, such as the A/D converter, EEPROM, temperature and I/O modules. There is
a coupler connected upstream of each communication branch. This coupler opens the branch for
the exchange of data.
Fig. 2.3 - 1 Principle of the 1-wire bus
2
2
Slave
Master
Coupler
E²
A/D A/DA/D I/O
Coupler
E²
°C I/O°C
E²
Slave