00197787-02_SI_SIPLACE_HeadVerification_EN - 第50页
6 Description of the test results 6.9 Dp- / Z-Positioning 50 Software Manual SIPLACE Head Verification 03/2018 6.9 Dp- / Z-Positioning 6.9.1 Measurement principle The Dp-/Z-Positioning measurement checks the deviation be…

6 Description of the test results
6.8 DP rotation test
Software Manual SIPLACE Head Verification 03/2018 49
6.8.3 Interpretation of the results obtained
‘DP rotation angle’ error for all segments
Cause Solution
Possible contamination of component camera ► Clean the lens or replace the component
camera.
‘DP rotation angle’ error for individual segments
Cause Solution
DP does not rotate reliably ► Replace the segment (DP).
Calibration component rotates on nozzle ► Check if the nozzle is dirty and clean it if
necessary.
► Check the nozzle seat.
► Check the vacuum supply.

6 Description of the test results
6.9 Dp- / Z-Positioning
50 Software Manual SIPLACE Head Verification 03/2018
6.9 Dp- / Z-Positioning
6.9.1 Measurement principle
The Dp-/Z-Positioning measurement checks the deviation between the Z-axis down light barrier
and the component sensor, in accordance with the angle setting of the segment. Each segment is
moved down and moved to an angle of 0°, 60°, 120°, 180°, 240° and 300°. For each angle, the
position is determined where the nozzle interrupts the beam of the component sensor and when
the light barrier is activated.
6.9.2 Measurement result
Fig.41: Result view – Dp-/Z-Positioning test
1 Measured Segment
2 Z Variation shows the difference between smallest and biggest value measured for Meas-
ure 1-6:
ZVariation = Measure
1-6max
- Measure
1-6min
3 CS Variation shows the difference between smallest and biggest value measured for
CSpos1-6:
CS Variation = CS
pos1-6max
- CS
pos1-6min
4 Measure 1-6 show the values measured when the Z-axis light barrier was interrupted.
5 CS pos 1-6 show the values measured when the component sensor was interrupted.

6 Description of the test results
6.9 Dp- / Z-Positioning
Software Manual SIPLACE Head Verification 03/2018 51
6.9.3 Interpretation of the results obtained
‘ZVariation’ and ‘CSVariation’ error for all segments
Cause Solution
Mechanical damage to Z-axis linear guide ► Replace the Z-axis drive.
Z-axis read unit dirty ► Clean the Z-axis read unit.
‘ZVariation’ error for individual segments
Cause Solution
Mechanical damage to Z-axis linear guide ► Replace the Z-axis drive.
Z-axis read unit dirty ► Clean the Z-axis read unit.
Linear guide of segment damaged ► Replace the linear guide of this segment.
Z-axis down light barrier of this segment pol-
luted
► Clean the light barrier and switching ring
through service gap.
‘CSVariation’ error for all segments
Cause Solution
Component sensor polluted ► Clean the prism at the component sensor.
Component sensor damaged ► Replace the component sensor.
‘CSVariation’ error for individual segments
Cause Solution
Linear guide of segment damaged ► Replace the linear guide.
Bad nozzle seating ► Check the nozzle interface and replace if
necessary.