00197787-02_SI_SIPLACE_HeadVerification_EN - 第56页

6 Description of the test results 6.12 Force measurement P&P module (TH) 56 Software Manual SIPLACE Head Verification 03/2018 6.12 Force measurement P&P module (TH) 6.12.1 Measurement principle During force measu…

100%1 / 90
6 Description of the test results
6.11 Force measurement for C&P heads
Software Manual SIPLACE Head Verification 03/2018 55
7 Values of the Force180° measurement
8 Values of the Force270° measurement
9 Graph showing the Force values for each segment.
10 Graph showing the Force values measured at the 4 different angles.
11 Graph showing a sample of the Force measurement in detail.
6.11.3 Interpretation of the results obtained
‘Force’ error for all segments
Cause Solution
Z-Axis strong running / defective Exchange of Z-axis if possible.
-Exchange head / send in head for repair.
‘Force’ error for individual segments
Cause Solution
Linear guide of segment (DP) strong run-
ning / defective
Exchange segment (DP).
6 Description of the test results
6.12 Force measurement P&P module (TH)
56 Software Manual SIPLACE Head Verification 03/2018
6.12 Force measurement P&P module (TH)
6.12.1 Measurement principle
During force measurement, the placement force is measured for the segment at several angles.
The following force measurements are available for P&P modules:
Force 1N (dynamic)
Force 2N (dynamic)
Force 5N (dynamic)
Force 10N (dynamic)
Force 15N (dynamic)
6.12.2 Measurement result
The following image shows an example of the Force2N(dynamic) measurement:
Fig.44: Result view – Force 2N (dynamic)
1 Table showing the Force measured at different angles.
2 Graph showing the Force measured at different angles and the limits specified.
3 Graph showing the Force measured at different angles in more detail.
4 Graph showing a sample of the Force measurement in detail.
6 Description of the test results
6.12 Force measurement P&P module (TH)
Software Manual SIPLACE Head Verification 03/2018 57
6.12.3 Interpretation of the results obtained
‘Force’ error
Cause Solution
Force sensor settings misaligned Adjust the spring force settings.
Force measuring unit defective Exchange the force measuring unit.
Exchange / repair the P&P module.
Trick & feather unit defective Exchange the Trick & feather unit.
Exchange / repair the P&P module.