Technical Service Manual 58 Revision Dat e: August 2004 FOR FUTURE USE CHECK THE “ ON - OFF - STOP” CIRCUIT The c onvey or will not run. Check the On/Of f/Stop c ircuits on the oven. POSSIBLE CAUSES The on/of f/s top cir…

100%1 / 133
Technical Service Manual 57 Revision Date: August 2004
CONVEYOR "JERKS" (MOTION IS NOT SMOOTH).
1. The chains are dirty and/or dry See: 24
2. Check the drive clutch See: 12
3. Check the excess belt / chain under the oven See: 23
4. Check the lube / operation of transfer gear See: 16
5. Unreliable output from the DC drive module See: 7
MEASURED SPEED IS NOT EQUAL TO DISPLAYED SPEED.
1. Run the conveyor calibration procedure See: 25
2. Check the encoder voltage See: 22
3. Check the encoder See: 20
4. Check the controller See: 15
Technical Service Manual 58 Revision Date: August 2004
FOR FUTURE USE
CHECK THE “ON - OFF - STOP” CIRCUIT
The conveyor will not run. Check the On/Off/Stop circuits on the oven.
POSSIBLE CAUSES
The on/off/stop circuit consists of the E-STOP switches, K37 & K38 relays, electrical enclosure interlock switches
(optional), F50, F52, F55, and the wiring and terminal strip connections.
HINT: First check the devices physically: the E-STOP switches should be “up”, The electrical enclosure interlock switches
should be depressed, K37 & K38 should be energized, and F50, F52 and F55 should “closed”. (not tripped).
After a physical check, check the connections of the conductors, look for them to be tight and correctly connected. If any
repairs were recently been performed in this area, look for a device that may have been improperly connected when the
work was done.
Finally, check all components' electrical integrity with a volt-ohm meter for correct voltage and internal resistance:
1 E-STOP switches.
2 Electrical enclosure interlock switches (optional).
3. K 37 & K38
4. F50, F52, F55
NOTE: If F50 or F52 trips (opens), the entire oven will lose control power.
2
1
Technical Service Manual 59 Revision Date: August 2004
CONVEYOR HAS NO POWER
The conveyor will not run
POSSIBLE CAUSES
Since the conveyor subsystem is an Electro-mechanical system, check the mechanical components before replacing
electrical parts. Ensure that the belt is not hung up below the oven, or that a board is not jammed somewhere on the
conveyor. After confirming that the mechanical elements of the conveyor are in operating order, start troubleshooting the
electrical components
The transformer secondary (F52) supplies power to ALL control circuits including the DC drive module.
One of the following is likely to be responsible:
1) F50, F52.
2) DC drive module.
3) Conveyor motor.
4) RT1 (motor inrush current limiter)
5) A1 I/O board (conveyor relay A1-K12).
6) Short in the wiring.
7) F67
K37 & K38 DOES NOT OPERATE
The conveyor will not run because K37 & K38 will not energize.
POSSIBLE CAUSES
If K37 & K38 will not energize, the conveyor will not operate.
Check the following components.
1) E-STOP switches.
2) G2 24vdc Power Supply.
3) Electrical enclosure interlock switches
4) K37 & K38.
5) F50, F52.
6) F55
The on/off/stop circuit consists of the E-STOP switches, K37 & K38, F50, F52, and F55 as well as the wiring and terminal
strips connecting the components.
HINT: First check the devices physically: the E-STOP switches should be “up”. K37 & K38 should be energized, and F50,
F52 and F55 should be “closed”. (not tripped).
After a physical check, check the wire connections... look for them to be tight and correctly connected. If any repairs were
recently been performed in this area, look for a device that may have been improperly connected when the work was
done.
Finally, check all components electrically with a volt-ohm meter for correct voltage and internal resistance. NOTE: If F50,
F52 or F55 open (trips), the entire oven will lose power.
3
4