00192402-01 - 第111页
GEM for SIPLACE V7.01 ©Siemens AG, all rights r eserved page 111 of 251 6) $ QQRWDWHG (YHQW5HSRUW6HQG S6F13 W * H<-E, Multiblock <L [3] <U4 DATAID> * DATAID <U4 CEID> * Collection Event…

GEM for SIPLACE V7.01
Page 110 of 251 ©Siemens AG, all rights reserved
6)(YHQW5HSRUW
S6F11 W * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<V> * Variable Value
...
>
>
...
>
> .
This message is the "normal" message that the Equipment uses to report events. In
order for this message to be used, the Equipment Constant "ConfigEvents" must be set to
"1".
A Collection Event has occurred at the Equipment. The Host has enabled event reporting
for this CEID (see S2F37). The Host has set the Equipment Constant RpType to "False"
(normal report format desired). The Equipment sends one or more Event Reports which
the Host has previously linked to that CEID (see S2F35). Each report contains specific
Variables which the Host has previously defined for that Report (see S2F33).
The Equipment generates a value for DATAID to uniquely identify this Conversation. If
S6F11 is multiblock, the Equipment first sends the S6F5/S6F6 Inquire/Grant transaction,
and the DATAID in S6F11 will match DATAID in S6F5.
If the CEID is enabled, but no Reports are linked to this CEID, S6F11 has the following
special format:
S6F11 W * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
6)(YHQW5HSRUW
S6F12 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the Event Report. The Equipment ignores ACKC6.

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 111 of 251
6)$QQRWDWHG(YHQW5HSRUW6HQG
S6F13 W * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<L [2]
<U4 VID> * Variable ID
<V> * Variable Value
>
...
>
>
...
>
> .
1RWH7KLVPHVVDJHLVSURYLGHGRQO\IRUFRPSDWLELOLW\ZLWKROGHU+RVWFRPSXWHUVZKLFK
VXSSRUWROGHUYHUVLRQVRI*(0
A Collection Event has occurred at the Equipment. The Host has enabled event reporting
for this CEID (see S2F37). The Host has set the Equipment Constant RpType to "True"
(Annotated report format desired). The Equipment Constant ConfigEvents has been set
to 1. The Equipment sends one or more Event Reports which the Host has previously
linked to that CEID (see S2F35). Each report contains specific Variables which the Host
has previously defined for that Report (see S2F33).
The Equipment generates a value for DATAID to uniquely identify this Conversation. If
S6F11 is multiblock, the Equipment first sends the S6F5/S6F6 Inquire/Grant transaction,
and the DATAID in S6F11 will match DATAID in S6F5.

GEM for SIPLACE V7.01
Page 112 of 251 ©Siemens AG, all rights reserved
If the CEID is enabled, but no Reports are linked to this CEID, S6F11 has the following
special format:
S6F13 W * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
6)$QQRWDWHG(YHQW5HSRUW
S6F14 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the Event Report. The Equipment ignore ACKC6.
6)(YHQW5HSRUW5HTXHVW
S6F15 W * H->E
<U4 CEID> . * Collection Event ID
The Host sends the CEID of interest, requesting normal format reports.
6)(YHQW5HSRUW'DWD
S6F16 * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<V> * Variable Value
...
>
>
...
>
> .
The Equipment sends one or more Event Reports which the Host has previously linked to
that CEID (see S2F35). Each report contains specific Variables which the Host has
previously defined for that Report (see S2F33).