GEM for SIPLACE V7.01 ©Siemens AG, all rights r eserved page 159 of 251 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ 3: barcode reader manuf ctured by LEUTZE in use RU the barcode could not be r ead 912011 SV A BC…

GEM for SIPLACE V7.01
Page 158 of 251 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
,'LYLVLRQ!
8&RPS&RXQW!
!
!
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
Barcode
912001 SV A BCINCENTERCONVEYOR
Barcode read from PCB in center conveyor. If no
barcode reader is installed in SIPLACE this variable
will contain an empty text
An empty text indicates an error on reading the
barcode.
912002 SV A BCININPUTCONVEYOR
Barcode read from PCB in input conveyor. If no
barcode reader is installed in SIPLACE this variable
will contain an empty text
An empty text indicates also an error on reading the
barcode.
912003 DV A COMPONENTBARCODE
Component barcode is read by the GUI.
An empty text indicates an error.
912004 DV U2 WAYOFINPUTCOMPONENTBARCODE
Way of reading the component barcode:
1: with keyboard
2: with barcode reader
912005 SV U2 PCBSIDEININPUTCONVEYOR
Side of the PCB showing the barcode (only valid in
case of two barcode reader per conveyor)
1: above
2: down
3: barcode reader manufctured by LEUTZE in use RU
the barcode could not be read
912006 SV U2 PCBSIDEINCENTERCONVEYOR
Side of the PCB showing the barcode (only valid in
case of two barcode reader per conveyor)
1: above
2: down

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 159 of 251
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
3: barcode reader manufctured by LEUTZE in use RU
the barcode could not be read
912011 SV A BCINTWINCENTERCONVEYOR
Barcode read from PCB in twin center conveyor. If no
barcode reader is installed in SIPLACE this variable
will contain an empty text.
An empty text indicates an error on reading the
barcode.
912012 SV A BCINTWININPUTCONVEYOR
Barcode read from PCB in twin input conveyor. If no
barcode reader is installed in SIPLACE this variable
will contain an empty text.
An empty text indicates also an error on reading the
barcode.
921015 SV U2 PCBSIDEINTWININPUTCONVEYOR
Side of the PCB showing the barcode (only valid in
case of two barcode reader per conveyor)
1: above
2: down
3: barcode reader manufctured by LEUTZE in use RU
the barcode could not be read
921016 SV U2 PCBSIDEINTWINCENTERCONVEYOR
Side of the PCB showing the barcode (only valid in
case of two barcode reader per conveyor)
1: above
2: down
3: barcode reader manufctured by LEUTZE in use RU
the barcode could not be read
912017 EC U1 BCREADEREXIST
Unables/Enables the event messages of the BCread
and BCTwinRead events.
0: No BCread and BCTwinRead events send
1: BCread and BCTwinRead events send (default)
GEM-Kernel
1002001 DV A GEMEVENTTEXT.
The equipment will set this string to contain a
description of the most recent event. The Host can
include this variable in any event report it defines.
Communication Model
1002002 EC U1 INITCOMMSTATE.
Initial (power-up) Communications State.

GEM for SIPLACE V7.01
Page 160 of 251 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
0 = Disabled
1 = Enabled
1002003 EC U2 ESTABLISHCOMMUNICATIONSTIMER.
Time in seconds of how long the equipment will pause
after an unsuccessful Connect Request before
sending another. Valid values are 0-32000.s
1002004 EC U1 CONFIGCONNECT.
An EC which controls which SECS message this
Equipment will use for Connect Request.
0 = S1F1
1 = S1F65
2 = S1F13
Control State Model
1002005 EC U1 INITCONTROLSTATE.
Initial (power-up) control superstate.
1 = Off-Line
2 = On-Line
1002006 SV U1 CONTROLSTATE.
The current Control State.
1 = Off-Line/Equipment Off-Line
2 = Off-Line/Attempt On-Line
3 = Off-Line/Host Off-Line
4 = On-Line/Local
5 = On-Line/Remote
1002007 SV U1 PREVIOUSCONTROLSTATE.
The Control State in effect before the most recent
transition to the current Control State.
1 = Off-Line/Equipment Off-Line
2 = Off-Line/Attempt On-Line
3 = Off-Line/Host Off-Line
4 = On-Line/Local
5 = On-Line/Remote
1002008 EC U1 ONLINEFAILED.
The default Control State transition when Attempt On-
Line fails.
1 = Equipment Off-Line
3 = Host Off-Line
1002009 EC U1 ONLINESUBSTATE.
The default (power-up) online substate of the Control