00192402-01 - 第181页
GEM for SIPLACE V7.01 ©Siemens AG, all rights r eserved page 181 of 251 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ ! )0D[/HDG 'HY!>PP@ )0D[%DOO'HY !>PP@ )2UWKR'HY !…

GEM for SIPLACE V7.01
Page 180 of 251 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
/
$&RPSRQHQW1DPH!
83DFNDJH)RUP1XPEHU!
85HVXOW!0:Ok; 1:Error
,0D[/HDG'HY!>PP@
!
The coplanarity module measures the height of all
leads and calculates then a hypothetical plane through
the three highest leads. 0D[/HDG'HY is the greatest
deviation between one lead and this plane.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1512014 SV L PLACEINFOIC
Placement information for IC-head 2 Only valid for
SIPLACE 80F. On a SIPLACE 80S this variable will
contain an empty list.
/
8;SRVLWLRQ!>PP@
8<SRVLWLRQ!>PP@
)$QJOH!>GHJUHHV@
8)RUFH,QGH[!
$5HIHUHQFH'HVLJQDWRU!
$&RPSRQHQW1DPH!
83DFNDJH)RUP1XPEHU!
83ODFHPHQW5HVXOW!
,3ODFHPHQW9DFXXP!
,9DFXXP!
8'DWD9DOLG!
,;GHYLDWLRQ!>PP@
,<GHYLDWLRQ!>PP@
)$QJOH!>GHJUHHV@
84XDOLW\!>@
8/HQJWK!>PP@
8:LGWK!>PP@
/
,3LWFKBSHUBOHDGBJURXS!
,3LWFKBSHUBOHDGBJURXS!

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 181 of 251
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
!
)0D[/HDG'HY!>PP@
)0D[%DOO'HY!>PP@
)2UWKR'HY!>GHJ@
8/HDG&RXQW!
!
The fields following the data item „DataVaild“
represent the result of optical centering. All fields are
not necessarily valid for all package forms. Verify the
validity of a field using the „data valid“ byte and refer to
the corresponding flag for the appropriate field.
[;GHY<GHYDQGDQJOH
[OHQJWKDQGZLGWK
[OHDGFRXQW
[SLWFK
[RUWKRJRQDOGHYLDWLRQ
[PD[OHDGGHYLDWLRQ
[PD[EDOOGHYLDWLRQ
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1512015 SV L PICKUPINFOIC
Pick-up information for IC-head . Only valid for
SIPLACE 80F. On a SIPLACE 80S this variable will
contain an empty list.
/
$&RPSRQHQW1DPH!
,7UDFN1XPEHU!
8)HHGHU7\SH!
,/HYHO!
,'LYLVLRQ!
80DFKLQH6LGH!
83LFN8S5HVXOW!
,3LFN8S9DFXXP!
,9DFXXP!
!
If the component was picked up from a feeder /HYHO
will contain -1. In the case that the component was
picked up from a tray in the waffle pack changer
7UDFN1XPEHU is set to -1. If both values are not equal

GEM for SIPLACE V7.01
Page 182 of 251 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
to -1 the component was picked up from a „manual
tray“.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1512016 SV L SEGMENTINFOIC
/
,&RPS3LFNHG8S!
,3LFN(UURUV!
,&RPS3ODFHG!
,3ODFH(UURUV!
!
The variable can be linked e.g. to event PCBReady. It
is reseted when a PCB reaches the center conveyor.
Rejected components due to optical centering or
coplanarity are not counted in PickErrors.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
I / O Ports
2012001 SV U1 INPUTPORTBYTE1
Bit 0: If bit is set, the upper proximity switch of the
lifting table is not switched.
Bit 1: If bit is set, the lower proximity switch of the
lifting table is not switched.
Bit 2: If bit is set, the proximity switch of the
stopper of the parallel conveyer is switched.
Bit 3: If bit is set, the proximity switch of the
adjustment width is switched.
Bit 4: If bit is set, the adjustment width is at the
limit switch.
Bit 5: If bit is set, the proximity switch of the
stopper is switched.
Bit 6: If bit is set, the software switch high voltage
is off.
Bit 7: If bit is set, the ceramic substrate centering
is open.
A value of -1 indicates an error
2012002 SV U1 INPUTPORTBYTE2
Bit 0: If bit is set, high voltage is on.
Bit 1: If bit is set, the emergency stop button is
down.