00192402-01 - 第216页

GEM for SIPLACE V7.01 Page 216 of 251 ©Siemens AG, all rights r eserved CEID Name De scripti on mi ni mum w i d th * 611025 FM_LSAUT_VERFAHRBER Conveyor belt target width outside travel range* 1 611026 FM_LSAUT_T IMEOUT …

100%1 / 251
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 215 of 251
7UDQVSRUW
CEID Name Description
611001 FM_TSP_ABGEGEBEN Interface signals to the preceding
station incorrect*
1
611002 FM_TSP_EBLS_NBED The input conveyor light barrier is not
covered*
1
611003 FM_TSP_EBLS_NFREI The input conveyor light barrier is not
released*
1
611004 FM_TSP_KLP_IM_EB No PCB on the input conveyor* 1
611005 FM_TSP_KERAM_ZENTR_OFF
EN
Ceramic substrate centering: x clamp
cannot be opened*
1
611006 FM_TSP_KERAM_ZENTR_GES
CHL
Ceramic substrate centering: x clamp
cannot be locked*
1
611007 FM_TSP_HUBT_UNT The lifting table cannot be moved
downwards*
1
611008 FM_TSP_HUBT_OB The lifting table cannot be moved
upwards*
1
611009 FM_TSP_MBLS_NFREI Center conveyor light barrier is not
released*
1
611010 FM_TSP_MBLS_NBED PCB does not reach the center
conveyor*
1
611011 FM_TSP_STOPPER_AUS Stopper jam during extension* 1
611012 FM_TSP_STOPPER_EIN Stopper jam during retraction* 1
611013 FM_TSP_KEINE_LP_IM_MB No PCB on the center conveyor* 1
611014 FM_TSP_ABLS_NBED PCB does not reach the output
conveyor*
1
611015 FM_TSP_ABLS_FBED Assignments of parallel output
conveyors not correct*
1
611016 FM_TSP_EB_BELEGT Input conveyor occupied* 1
611017 FM_TSP_MB_BELEGT Center conveyor occupied* 1
611018 FM_TSP_AB_BELEGT Output conveyor occupied* 1
611019 FM_LSS_PROXIMITY
SWITCH_N_BED
Proximity switch of left table side is not
activated*
1
611020 FM_LSS_MAX_SCHRITT Error in axis programming (left table
side) *
1
611021 FM_LSS_PROXIMITY
SWITCH_N_FREI
Proximity switch of left table side
responding constantly*
1
611022 FM_LSS_LP_IM_TSP PCB in conveyor during width
adjustment*
1
611023 FM_LSS_ENDSCHALT_AUS Width adjustment at limit switch
maximum width*
1
611024 FM_LSS_ENDSCHALT_ZU Width adjustment at limit switch 1
GEM for SIPLACE V7.01
Page 216 of 251 ©Siemens AG, all rights reserved
CEID Name Description
minimum width*
611025 FM_LSAUT_VERFAHRBER Conveyor belt target width outside
travel range*
1
611026 FM_LSAUT_TIMEOUT Conveyor belt target width cannot be
set (timeout) *
1
611027 FM_LSAUT_BEIDE_ENDS Both limit switches of width
adjustment actuated*
1
611028 FM_LSAUT_ENDSCHALT_ZU Limit switch of width adjustment for
minimum width actuated*
1
611029 FM_LSAUT_ENDSCHALT_AUS Limit switch of width adjustment for
maximum width actuated*
1
611030 FM_LSK_MAX_SCHRITT Proximity switch not found during
conveyor belt width check*
1
611031 FM_LSK_PROXIMITY
SWITCH_N_FREI
Proximity switch switched before
conveyor belt width check*
1
610031 PCBreachedInputConveyor The light barrier of the input conveyor
signals the arrival of a PCB and
<INPUTCONVEYORSTATE> will be
updated
1
610032 PCBreachedCenterConveyor The light barrier of the center
conveyor signals the arrival of a PCB
,<INPUTCONVEYORSTATE> and
<CENTERCONVEYORSTATE> will
be updated
1
610033 PCBreachedOutputConveyor The light barrier of the output
conveyor signals the arrival of a PCB,
<CENTERCONVEYORSTATE> and
<OUTPUTCONVEYORSTATE> will
be updated
1
610034 PCBreachedInputConveyor2 The light barrier of the input conveyor
on twin side signals the arrival of a
PCB and
<TWININPUTCONVEYORSTATE>
will be updated
1
610035 PCBreachedCenterConveyor2 The light barrier of the center
conveyor on twin side signals the
arrival of a PCB,
<TWININPUTCONVEYORSTATE>
and
<TWINCENTERCONVEYORSTATE>
will be updated
1
610036 PCBreachedOutputConveyor2 The light barrier of the output
conveyor on twin side signals the
arrival of a PCB,
<TWINCENTERCONVEYORSTATE>
and
<TWINOUTPUTCONVEYORSTATE>
will be updated
1
610037 TransportWidthMeasured The SIPLACE finished the
measurement of the
4
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 217 of 251
CEID Name Description
<TRANSPORTWIDTH>
610038 StopperUp Stopper up 1
610039 StopperDown Stopper down 1
610040 LiftTableUp Lifting table up 1
610041 LiftTableDown Lifting table down 1
610042 CerCenterUp Ceramic substrate centering up 1
610043 CerCenterDown Ceramic substrate centering down 1
610044 TransportWidthMeasured2 The SIPLACE finished the
measurement of the
<TWINTRANSPORTWIDTH>on twin
side
47
610045 StopperUp2 Stopper up on twin side 1
610046 StopperDown2 Stopper down on twin side 1
610047 LiftTableUp2 Lifting table up on twin side 1
610048 LiftTableDown2 Lifting table down on twin side 1
610049 CerCenterUp2 Ceramic substrate centering up on
twin side
1
610050 CerCenterDown2 Ceramic substrate centering down on
twin side
1
610051 TakeOutInConv A PCB was taken out of the input
conveyor and
<INPUTCONVEYORSTATE> will be
updated
1
610052 TakeOutOutConv A PCB was taken out of the output
conveyor and
<OUTPUTCONVEYORSTATE> will
be updated
1
610053 TakeOutInConv2 A PCB was taken out of the input
conveyor on twin side and
<TWININPUTCONVEYORSTATE>
will be updated
1
610054 TakeOutOutConv2 A PCB was taken out of the output
conveyor on twin side and
<TWINOUTPUTCONVEYORSTATE>
will be updated
1
611055 FM_BRV_AUT_SYN Autom. width adjustment not possible
in SYNCHRONOUS transport mode
1
611056 FM_BRV_SUCH_VER Conveyor belt width out of travel range 1
611057 FM_TSP_ABLS_NFREI Sensor of the output conveyor not
released
1
611058 FM_TSP_ANGEKOMMEN next station cant take over PCB 1
* Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these fiducials
collection events.