00192402-01 - 第60页

GEM for SIPLACE V7.01 Page 60 of 251 ©Siem ens AG, all rights reserved used in: S2F39, S6F5 'DWD9DOLG The f ields following the data item „ DataValid “ r epresent the res ult of optical c entering. All fields ar e n…

100%1 / 251
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 59 of 251
SEGMENTINFOIC:
Number of components which were placed successfully by the actual
nozzle.
Format:I2
used in : GANTRYINFO1, GANTRYINFO2, GANTRYINFOIC, SEGMENTINFOREV1,
SEGMENTINFOREV2, SEGMENTINFOIC
&RPSRQHQW1DPH - Name of a component
Format: A
used in: PLACEINFOREV1, PLACEINFOREV2, PICKUPINFOREV1
PICKUPINFOREV2, VISIONDATAIC, COPLANARITYDATAIC,
INVENTARYWPC, PARTNRPLACEIC,
&RSODQDULW\(UURUV -Number of coplanarity errors since last download of a process
program
Format: U2
used in: PICKUPERRORS
&3$&. - Command Parameter Acknowledge Code
Format: B[1]
1 = Parameter Name does not exist
2 = Illegal value specified for CPVAL
3 = Illegal format specified for CPVAL
4 = PP not in library
>4 = other equipment specific error
4- 63 reserved
used in: S2F22, S2F28
&31$0( - Command Parameter Name
Format: A
used in: S2F41, S2F42
&39$/ - Command Parameter Value
Format:
used in: S2F41
FXELFBQR]]OH Vacuum value for a nozzle
threshold for cubic components
Format: I4
Units are mbar
used in : VACUUMDATEREV1, VACUUMDATAREV2, VACUUMDATAIC
'$7$,' - Data ID
Format:
used in: S2F33, S2F35, S2F39, S2F49, S6F3, S6F5, S6F9, S6F11, S6F13, S6F13,
S6F16, S6F18
'$7$/(1*7+ - Data Length
Format: U4
GEM for SIPLACE V7.01
Page 60 of 251 ©Siemens AG, all rights reserved
used in: S2F39, S6F5
'DWD9DOLG
The fields following the data item DataValid represent the result of optical centering. All
fields are not necessarily valid for all package forms. Verify the validity of a field using the
data valid byte and refer to the corresponding flag for the appropriate field.
0x0001 X-dev, Y-dev. and angle
0x0002 length and width
0x0004 lead count
0x0008 pitch
0x0010 orthogonal deviation
0x0020 max. lead deviation
0x0040 max. ball deviation
'LYLVLRQ - Division at a feeder or a level in the waffle pack changer
Format: I2
used in: PICKUPINFO1, PICKUPINFO2, INVENTARYWPC, DIVISIONIC
'5$&. - Define Report Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one RPTID already defined
4 = Denied. At least one VID does not exist
>4 = Other errors
5 - 63 reserved
used in: S2F34
'63(5 Data Sample Period
Format: A
used in: S2F23
($& - Equipment Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. At least one constant does not exist
2 = Denied. Busy
3 = Denied. At least one constant out of range
>3 = Other errors
4 - 63 reserved
used in: S2F16
(&'() - Equipment Constant Default Value
Format:
used in: S2F30
(&0$; - Equipment Constant MaximumValue
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 61 of 251
Format:
used in: S2F30
(&0,1 - Equipment Constant Minimum Value
Format:
used in: S2F30
(&1$0( - Equipment Constant Name
Format:
used in: S2F30
(5$&. - Enable/Disable Event Report
Format: B[1]
0 = Accept
1 = Denied. At least one CEID does not exist
>1 = Other errors
2 - 63 reserved
used in: S2F38
)&1,' - Function Identification
Format: U1
used in: S2F43, S2F44
)HHGHU$FFHVVHV3HU3&% Number of feeder accesses per PCB
Format: U2
used in: PICKUPERRORS
)HHGHU7\SHIdentifier for a feeder
Format: U2
1 Linear 4.5 mm
2 Linear 9.5 mm
3 Linear 10 mm
4 Linear 14 mm
5 Linear 30 mm
6 0402_0603
151 Fimecore
152 Nitto
7 8 mm tape, electric, 2 x cycle
8 8 mm tape, electric
9 8 mm tape, mechanical, 2 x cycle
10 8 mm tape, mechanical
29 8mm tape "long" 2mm manual
19 8mm tape "long" 4mm manual
149 8mm tape long 8mm
150 8mm "Schulz" tape
11 12mm tape "long"
12 16mm tape "long"
14 24mm "Blister" tape
16 32mm "Blister" tape
15 32mm "Paper" tape
17 44mm tape
18 56mm tape
56 24mm type III
57 32mm type III
58 44mm type III