GEM for SIPLACE V7.01
Page 60 of 251 ©Siemens AG, all rights reserved
used in: S2F39, S6F5
'DWD9DOLG
The fields following the data item „DataValid“ represent the result of optical centering. All
fields are not necessarily valid for all package forms. Verify the validity of a field using the
„data valid“ byte and refer to the corresponding flag for the appropriate field.
0x0001 X-dev, Y-dev. and angle
0x0002 length and width
0x0004 lead count
0x0008 pitch
0x0010 orthogonal deviation
0x0020 max. lead deviation
0x0040 max. ball deviation
'LYLVLRQ - Division at a feeder or a level in the waffle pack changer
Format: I2
used in: PICKUPINFO1, PICKUPINFO2, INVENTARYWPC, DIVISIONIC
'5$&. - Define Report Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one RPTID already defined
4 = Denied. At least one VID does not exist
>4 = Other errors
5 - 63 reserved
used in: S2F34
'63(5 Data Sample Period
Format: A
used in: S2F23
($& - Equipment Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. At least one constant does not exist
2 = Denied. Busy
3 = Denied. At least one constant out of range
>3 = Other errors
4 - 63 reserved
used in: S2F16
(&'() - Equipment Constant Default Value
Format:
used in: S2F30
(&0$; - Equipment Constant MaximumValue

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 61 of 251
Format:
used in: S2F30
(&0,1 - Equipment Constant Minimum Value
Format:
used in: S2F30
(&1$0( - Equipment Constant Name
Format:
used in: S2F30
(5$&. - Enable/Disable Event Report
Format: B[1]
0 = Accept
1 = Denied. At least one CEID does not exist
>1 = Other errors
2 - 63 reserved
used in: S2F38
)&1,' - Function Identification
Format: U1
used in: S2F43, S2F44
)HHGHU$FFHVVHV3HU3&%– Number of feeder accesses per PCB
Format: U2
used in: PICKUPERRORS
)HHGHU7\SHIdentifier for a feeder
Format: U2
1 Linear 4.5 mm
2 Linear 9.5 mm
3 Linear 10 mm
4 Linear 14 mm
5 Linear 30 mm
6 0402_0603
151 Fimecore
152 Nitto
7 8 mm tape, electric, 2 x cycle
8 8 mm tape, electric
9 8 mm tape, mechanical, 2 x cycle
10 8 mm tape, mechanical
29 8mm tape "long" 2mm manual
19 8mm tape "long" 4mm manual
149 8mm tape „long“ 8mm
150 8mm "Schulz" tape
11 12mm tape "long"
12 16mm tape "long"
14 24mm "Blister" tape
16 32mm "Blister" tape
15 32mm "Paper" tape
17 44mm tape
18 56mm tape
56 24mm type III
57 32mm type III
58 44mm type III

GEM for SIPLACE V7.01
Page 62 of 251 ©Siemens AG, all rights reserved
59 56mm type III
60 S_G_12_S
61 S_G_16_S
62 S_G_24_S
63 S_G_32_S
64 S_G_44_S
65 S_G_56_S
30 waffle-pack tray
used in: PICKUPINFO1REV1, PICKUPUPREV2, PICKUPIC
)LGXFLDO1XPEHUIdentifier of a fiducial
Format: U2
used in: TAUGHTFIDUCIAL, FIDUCIALDATA
)RUFH,QGH[ - programmed placement force
see chapter 3.5 in the SIPLACE Data Interface for a detailed description.
Format: U1
used in: PLACEINFOREV1, PLACEINFOREV2
*$175<*5283,' – ID of the gantry-group
Format: U2
0 = first gantrygroup in direction of transport
9 = not defined
*$175<,' – ID of the gantry
Format: U2
0 = gantry on the left side in direction of transport
1 = gantry on the right side in direction of transport
9 = not defined
*5$17 - Permission to send
Format: B[1]
0 = Permission granted
1 = Busy, try again
2 = Not interested
>2 = Other errors
3 - 63 reserved
used in: S6F6
+&$&. - Host Command Parameter Acknowledge Code
Format: B[1]
0 = Accept, Command has been performed
1 = Command does not exist
2 = Cannot perform now
3 = At least one parameter is invalid
4 = Acknowledge, command will be performed with completion signaled later by an
event
5 = Rejected. Already in desired condition