GEM for SIPLACE V7.01 Page 62 of 251 ©Siem ens AG, all rights reserved 59 56m m type III 60 S_G _12_S 61 S_G _16_S 62 S_G _24_S 63 S_G _32_S 64 S_G _44_S 65 S_G _56_S 30 waf fle-pack tray used in: PICKUPINFO1REV1 , PICKU…

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 61 of 251
Format:
used in: S2F30
(&0,1 - Equipment Constant Minimum Value
Format:
used in: S2F30
(&1$0( - Equipment Constant Name
Format:
used in: S2F30
(5$&. - Enable/Disable Event Report
Format: B[1]
0 = Accept
1 = Denied. At least one CEID does not exist
>1 = Other errors
2 - 63 reserved
used in: S2F38
)&1,' - Function Identification
Format: U1
used in: S2F43, S2F44
)HHGHU$FFHVVHV3HU3&%– Number of feeder accesses per PCB
Format: U2
used in: PICKUPERRORS
)HHGHU7\SHIdentifier for a feeder
Format: U2
1 Linear 4.5 mm
2 Linear 9.5 mm
3 Linear 10 mm
4 Linear 14 mm
5 Linear 30 mm
6 0402_0603
151 Fimecore
152 Nitto
7 8 mm tape, electric, 2 x cycle
8 8 mm tape, electric
9 8 mm tape, mechanical, 2 x cycle
10 8 mm tape, mechanical
29 8mm tape "long" 2mm manual
19 8mm tape "long" 4mm manual
149 8mm tape „long“ 8mm
150 8mm "Schulz" tape
11 12mm tape "long"
12 16mm tape "long"
14 24mm "Blister" tape
16 32mm "Blister" tape
15 32mm "Paper" tape
17 44mm tape
18 56mm tape
56 24mm type III
57 32mm type III
58 44mm type III

GEM for SIPLACE V7.01
Page 62 of 251 ©Siemens AG, all rights reserved
59 56mm type III
60 S_G_12_S
61 S_G_16_S
62 S_G_24_S
63 S_G_32_S
64 S_G_44_S
65 S_G_56_S
30 waffle-pack tray
used in: PICKUPINFO1REV1, PICKUPUPREV2, PICKUPIC
)LGXFLDO1XPEHUIdentifier of a fiducial
Format: U2
used in: TAUGHTFIDUCIAL, FIDUCIALDATA
)RUFH,QGH[ - programmed placement force
see chapter 3.5 in the SIPLACE Data Interface for a detailed description.
Format: U1
used in: PLACEINFOREV1, PLACEINFOREV2
*$175<*5283,' – ID of the gantry-group
Format: U2
0 = first gantrygroup in direction of transport
9 = not defined
*$175<,' – ID of the gantry
Format: U2
0 = gantry on the left side in direction of transport
1 = gantry on the right side in direction of transport
9 = not defined
*5$17 - Permission to send
Format: B[1]
0 = Permission granted
1 = Busy, try again
2 = Not interested
>2 = Other errors
3 - 63 reserved
used in: S6F6
+&$&. - Host Command Parameter Acknowledge Code
Format: B[1]
0 = Accept, Command has been performed
1 = Command does not exist
2 = Cannot perform now
3 = At least one parameter is invalid
4 = Acknowledge, command will be performed with completion signaled later by an
event
5 = Rejected. Already in desired condition

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 63 of 251
6 = control state is not remote
7 = recipe not in library
8 = control mode is not „GEM-Host“
9 = bad PP-Body
10 - 63 reserved
used in: S2F42
+($',' – ID of the head
Format: U2
0 = first head in the machine (RV-Head)
1 = second head in the machine (IC-head in case of a F4/F5 machine, second RV-
head in case of a S20/S23 machine)
9 = not defined
+(,*+72)5(92/9(5 distance between the head and the transport conveyor
During the reference run, the SIPLACE machines measures the difference between the
upper edge of the transport conveyor and the nozzle on segment 1. The
HEIGHTREVOLVER is then calculated by subtracting the length of the nozzle on segment
1 form the measured value. The nozzle length is defined in the machine data. So
HEIGHTREVOLOR is a relative, not an absolute value.
Format:I4
Units are 1/1000 mm
used in : HEIGHTREVOLVER1, HEIGHTREVOLVER2, HEIGHTIC
/HDG&RXQW - Number of lead found during package form measurement
Format: U2
used in: PLACEINFOREV1, PLACEINFOREV2, VISIONDATAIC
/HQJWK- Length of a package form
Length is returned from the vision system. It’s the „optical“ length of the package form.
Units are 1/1000 mm
Format: U4
used in: PLACEINFOREV1, PLACEINFOREV2, VISIONDATAIC
/HYHO- Level in the waffle pack changer
Level 1 is the lowest level in waffle pack changer, level 28 the top most. A value of 0
indicates the manual tray.
If the component was picked up from a feeder Level will contain -1.
Format: I2
used in: PICKUPINFOREV1, PICKUPINFOREV2, LEVELNRIC
/,0,7$&. - Acknowledgment code for variable limit attribute set
Format: B[1]
1 = LIMITID does not exist
2 = UPPERDB < LIMITMAX
3 = LOWERDB >LIMITMIN
4 = UPPERDB < LOWERDB
5 = Illegal format specified for UPPERDB or LOWERDB