00192402-01 - 第65页
GEM for SIPLACE V7.01 ©Siemens AG, all rights r eserved page 65 of 251 9 = not def ined 0D[%DOO'HY - Max im al ball deviation MaxBallDev is calc ulated by the vision sy stem during the optical center ing of a pack a…

GEM for SIPLACE V7.01
Page 64 of 251 ©Siemens AG, all rights reserved
6 = ASCII value cannot be translated to numeric
7 = Duplicate limit definition for this variable
>7 = Other errors
8 - 63 reserved
used in: S2F46
/,0,7,' - Limit ID
Format: B[1]
used in: S2F45, S2F46, S2F48
/,0,70$; - maximum limit
Format:
used in: S2F48
/,0,70,1 - minimum limit
Format:
used in: S2F48
/2:(5'% - lower boundary of the deadband for a limit
Format
used in: S2F45, S2F48
/5$&. - Limit Report Acknowledge Code
Format: B[1]
0 = Accepted
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one CEID link already defined
4 = Denied. At least one CEID does not exist
5 = Denied. At least one RPTID does not exist
>5 = Other errors
6 - 63 reserved
used in: S2F36
/9$&. - Variable limit definition acknowledge code
Format: B[1]
1 = Variable does not exist
2 = Variable has no limits capability
3 = Variable repeated in message
4 = Limit value error as desired in LIMITACK
5 - 63 reserved
used in: S2F46
0DFKLQH6LGH - Side of the machine
Format: U1
0 = right side in transport direction
1 = left side in transport direction

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 65 of 251
9 = not defined
0D[%DOO'HY - Maximal ball deviation
MaxBallDev is calculated by the vision system during the optical centering of a package
form. It is calculated over all balls in all ball groups.
Format: F8
Units are 1/1000 mm
used in: PLACEINFOREV1, PLACEINFOREV2, VISIONDATAIC
0D[/HDG'HY - Maximum lead deviation
MaxLeadDev is calculate by the vision system during the optical centering of a package
form. It is calculate over all leads in all lead groups.
Format: F8
Units are 1/1000 mm
used in: PLACEINFOREV1, PLACEINFOREV2, VISIONDATAIC, COPLANARITYDATAIC
0'/1 - Equipment Model Type
Format: A
used in: S1F2, S1F13, S1F14, S1F65, S1F66
0+($' - Message block header associated with block in error
Format: B[16]
used in: S9F1, S9F3, S9F5, S9F7, S9F11
0,' - Lot ID
Format: A[16]
used in S2F27
QRWBFXELFBQR]]OH Vacuum value for a nozzle
vacuum threshold for melfs, etc.
Format: I4
Units are mbar
used in : VACUUMDATEREV1, VACUUMDATAREV2, VACUUMDATAIC
12==/(B7<3(: - Number of a nozzle
For a detailed description see „SIPLACE Placement Stations - Data Interface: Chapter
Nozzle Types“.
Format: U4
used in : NOZZLECONF1, NOZZLECONF2, NOZZLECONFIC, NOZZLERETURN
21/$&. Acknowledge for code for ON-LINE request
Format: B[1]
0 = Accepted
1 = Denied
2 = Equipment already ON-LINE
3 - 63 reserved
used in S1F18
RSHQBQR]]OH Vacuum value for a nozzle
vacuum value measured with an open nozzle

GEM for SIPLACE V7.01
Page 66 of 251 ©Siemens AG, all rights reserved
Format: I4
Units are mbar
used in : VACUUMDATEREV1, VACUUMDATAREV2, VACUUMDATAIC
2SWLFDO(UURUVNumber of optical errors since last download of a process program
Format: U2
used in: PICKUPERRORS
2UWKR'HY - Orthogonal deviation
Format: F8
Units are 1/100 degree
used in : PLACEINFOREV1, PLACEINFOREV2, PLACEINFOIC
3DFNDJH)RUP1XPEHU - Identifier for a package form
Format: U2
see chapter 9 in the SIPLACE Data Interface ( <pack_form_no>).
used in: PLACEINFOREV1, PLACEINFOREV2, VISIONDATAIC, COPLANARITYIC,
MODIFIEDPACKGEFORM
3LFN(UURUVNumber of pickup errors per segment since the current PCB reached the
center conveyor.
SEGMENTINFOIC: Number of pickup errors of the actual nozzle.
Format:I2
used in : SEGMENTINFOREV1, SEGMENTINFOREV2, SEGMENTINFOIC
3LFN8S(UURUVNumber of pick-up errors since last download of a process program
Format: U2
used in: PICKUPERRORS
3LFN8S3ODFH(UURUV Number of pickup and place errors per segment since the
current PCB reached the center conveyor.
Format:I2
used in : SEGMENTINFOREV1, SEGMENTINFOREV2
3LFN8S5HVXOW - Result of the pick up action
Format : U1
0 NOK (default value)
1 OK
2 NOK
used in : PLACEINFOREV1, PLACEINFOREV2
3LFN8S9DFFXP - Vaccum measured at pick-up position.
PickUpVacuum is measured in the pick up circuit after a component is picked up
Format : I4
Units are mbar
used in : PICKUPINFOREV1, PICKUPINFOREV2,
3LWFKBSHUBOHDGBJURXS- Distance between leads.