00192402-01 - 第71页
GEM for SIPLACE V7.01 ©Siemens AG, all rights r eserved page 71 of 251 used in: PLACEINFO REV1, PLACEINFOR EV2, PICKUPINFOREV1, PIC KUPINFOREV2, 9,' - Variable ID Format: used in: S1F3, S1F11, S2F13, S2F 15, S2F29, …

GEM for SIPLACE V7.01
Page 70 of 251 ©Siemens AG, all rights reserved
4 - 63 reserved
used in; S2F24
7,$&. - Time Acknowledge Code
Format: B[1]
0=OK
1 = Error, not done
2 - 63 reserved
used in; S2F32
7,' - Terminal ID
Format: B[1]
0 = single or main terminal
>0 = additional terminals on same equipment
used in: S10F1, S10F3, S10F5
727603 - Total sample to be made
Format: U4
used in: S2F23
7UDFN1XPEHU - Number of a track
Format: I2
used in: PICKUPINFO1REV1, PICKUPUPREV2, PICKUPERRORS
WROBGLUW\BQR]]OH - vacuum value
Format: I4
Units are mbar
used in : VACUUMDATEREV1, VACUUMDATAREV2, VACUUMDATAIC
WROBOHDN\BQR]]OH - vacuum value
Format: I4
Units are mbar
used in : VACUUMDATEREV1, VACUUMDATAREV2, VACUUMDATAIC
75,' - Trace Request ID
Format: U4
used in: S2F23 S6F1
81,76 - Units of measure
Format: A
used in: S1F12, S2F30, S2F48
833(5'% - Upper boundary of the dead-end of a limit
Format:
used in: S2F45, S2F48
9DFXXP- Vacuum in the holding circuit.
Format: I4
Vacuum is the measured vacuum in the holding circuit.
Units are mbar

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 71 of 251
used in: PLACEINFOREV1, PLACEINFOREV2, PICKUPINFOREV1, PICKUPINFOREV2,
9,' - Variable ID
Format:
used in: S1F3, S1F11, S2F13, S2F15, S2F29, S2F30, S2F33, S2F45, S2F46, S6F3,
S6F13, S6F18, S6F22
9/$$&. - Variable Limit Attribute Acknowledge Code
Format: B[1]
0=OK
1 = Limit attribute definition error
2 = Cannot perform now
3 = Other error
4 - 63 reserved
used in: S2F46
:LGWK- Width of a package form
Width is returned from the vision system. It’s the „optical“ width of the package form.
Units are 1/1000 mm
Format: U4
used in: PLACEINFOREV1, PLACEINFOREV2, VISIONDATAIC
;SRVLWLRQ - X-Coordinate of a placement or fiducial position
Format: U4
Units are 1/1000 mm
;GHYLDWLRQ - Deviation in X-direction
Format: I4
Units are 1/1000 mm
<SRVLWLRQ - Y-Coordinate of a placement or fiducial position
Format: U4
Units are 1/1000 mm
<GHYLDWLRQ - Deviation in Y-direction
Format: I4
Units are 1/1000 mm

GEM for SIPLACE V7.01
Page 72 of 251 ©Siemens AG, all rights reserved
6WUHDP
6)$UH<RX7KHUH
S1F1 W. * H<->E
The Host may send this message to the Equipment at any time.
The SIPLACE sends this message periodically as a "heartbeat" to determine if the SECS
link is operational.
The Equipment Constant ConfigConnect can be set to cause the Equipment to send
S1F1 instead of S1F13 for Connect Request.
6)2Q/LQH'DWD(TXLSPHQWWR+RVW
S1F2 * H<-E
<L
<A MDLN> * MDLN Model Number
<A SOFTREV> * SOFTREV Software Revision
> .
The Equipment reports its Model Number and Software Revision.
6)2Q/LQH'DWD+RVWWR(TXLSPHQW
S1F2 * H->E
<L> .
6)6HOHFWHG6WDWXV5HTXHVW
S1F3 W * H-> E
<L
<U4 VID> * Variable ID
...
> .
The Host requests status from the SIPLACE. The Host sends the VIDs of interest.
Several VIDs can be specified if desired.
Normally, only VIDs of class SV (i.e. Status Variables) are used in this message.
However, the SIPLACE allows the Host to use any VID of class DV, EC, or SV.
If S1F3 contains a zero-length list, then the SIPLACE will report all variables of class SV,
in order by VID.