00193733-02.pdf - 第66页

2 Assembly Instructions PCB Camera, Multicolor SIPLACE F5 HM SIPLACE F5 HM 2.6 Assembly Terminal panels and Illumination cable 05/2007 Edition 66 : In the 2nd step run the top ribbon cabl e down and plu g it in (Abb. 2.6…

100%1 / 88
SIPLACE F5 HM 2 Assembly Instructions PCB Camera, Multicolor SIPLACE F5 HM
05/2007 Edition 2.6 Assembly Terminal panels and Illumination cable
65
2
Abb. 2.6.10 1st Step while Laying Cable in the Area of the Head PCB
Key to Abb. 2.6.10: 2
1. Cable "Illumination" of PCB camera Multicolor
2. Cable "Illumination" -> plug-in connection X3 (PCB camera board, modular)
3. Cable "Camera" of PCB camera Multicolor
4. Cable "Camera" -> plug-in connection X4 (Vision board, modular)
5. Cable tie: fastening of cable "Camera" of PCB camera Multicolor *)
6. Cable tie: fastening the cable "Illumination" of PCB camera Multicolor
NOTE:
The cable be laid ON the PCB and, in order for the head cover to fit, the cable is not to protrude
over the sides. The cable is fastened to the vision board with cable ties. 2
2
1
1
4
3
5
2
6
2 Assembly Instructions PCB Camera, Multicolor SIPLACE F5 HM SIPLACE F5 HM
2.6 Assembly Terminal panels and Illumination cable 05/2007 Edition
66
: In the 2nd step run the top ribbon cable down and plug it in (Abb. 2.6.11).
: Push the ribbon cable retaining clamp into the particular position shown.
: Make certain that all of the plug-in connections are secure.
Abb. 2.6.11 2nd Step while Laying Cable in the Area of the Head PCB
Key: 2
1. In connection with laying the "Camera cable", comply with the NOTE below the key to Abb.
2.6.10.
1
SIPLACE F5 HM 2 Assembly Instructions PCB Camera, Multicolor SIPLACE F5 HM
05/2007 Edition 2.6 Assembly Terminal panels and Illumination cable
67
2.6.7 Assembling the Placement Head and the Machine
: Place the cover previously removed back on the placement head (see NOTE in Abschn. 2.1).
Fasten the covers with 5 screws each.
: Place the covers on to cable pits.
: Re-install the servo unit (socket hex head cap screw M5).
: Apply screw-locking compound to the screw.
: Remove all of the tools, etc., from the machine’s working area.
: Before docking the movable component changeover table, push the gantry until it is over the
PCB conveyor area.
: Close the machine frame doors on the terminal panel left and right (see Abb. 2.6.1 and Abb.
2.6.3).
: Lock the doors of the machine frame.
: Turn the machine ON at the main switch. The compressed air must be connected.
: Dock all movable component changeover tables with the previous allocation.
: Install the cover of the feeder modules over the component changeover tables (see Fig. 2.6.1).
: Close the safety doors and safety hoods.
: Resume the work with the configuration at the line.