1_H24维修手册.pdf - 第103页
E d it io n 5 .0 H 24 H ead R ep ai r T r ai n i n g T ext f o r S er vi ce E n g i n e e r s M e asu r i n g t h e A i r P r e ssu r e o n th e Ma c h i n e 5. U s e t he han dy m ano m et er t o c hec k t hat t he v ac…

Edition 5.0 H24 Head Repair Training Text for Service Engineers
Measuring the Air Pressure on the Machine
7. If the nozzle cleaning pressure is outside the tolerance, check that the syringe O-ring
and pin are properly inserted. Also check that the spool valve O-ring is not damaged.
Caution: Replace damaged parts as necessary.
8.4 Measuring the Vacuum Pressure
1. Measure the vacuum pressure. Use IO monitor to turn ON [Y006 PARTS VACUUM
PUMP ON] and [Y008 BASE COOLING FAN ON].
2. Prepare the vacuum measurement jigs (AA1ZT0*, 2AGKHJ01520*)
3. Attach the vacuum pressure measurement jig to the holder you wish to measure.
4. Lower the syringe spool valve only for the holder you wish to measure and raise all the
other spool valves.
Vacuum measurement nozzle
jig (2AGKHJ01520*)
Vacuum pressure
Target -90kpa or less
Measuring spool
FK-9F50-08-0E 8-6 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8

Edition 5.0 H24 Head Repair Training Text for Service Engineers
Measuring the Air Pressure on the Machine
5. Use the handy manometer to check that the vacuum pressure is within the tolerance
range of -90 kPa.
Note: Tolerance values are for new heads and should only be used as a reference
for used heads.
Note: The tolerance range of the vacuum pressure depends on the air source
pressure of the vacuum pump installed in the Base. Ensure that the air source
pressure of the vacuum pump which is displayed on the vacuum sensor on the base
front side is inside the range of -85.0 kPa to -91.8 kPa.
FK-9F50-08-0E 8-7 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8

Edition 5.0 H24 Head Repair Training Text for Service Engineers
Measuring the Air Pressure on the Machine
MEMO:
FK-9F50-08-0E 8-8 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8