1_H24维修手册.pdf - 第131页

E d it io n 5 .0 H 24 H ead R ep ai r T r ai n i n g T ext f o r S er vi ce E n g i n e e r Pro p e r D at a M e asu r em en t 7. T he f ol l ow i ng m es s a ge d i s pl ay s w hen m o v i ng t o t he pos i t i on f or …

100%1 / 214
Edition 5.0 H24 Head Repair Training Text for Service Engineer
Proper Data Measurement
5. In order to make the measurement easier, lower the Z axis and tighten the coupling
where the jig is parallel to the X-axis and the pulse count at this position is 30000 ±
3000 pulses. The servo counter at this position will be the proper data for A-holder
Q-axis.
(Coupling tightening torque: 0.4 Nm)
6. This manual explains the measurement by using [ALL], so after the A-holder Q-axis
proper data measurement, select [OK] to automatically rotate the R-axis to move to
the B-holder proper data measurement.
Pins should
align vertically
FK-9F50-08-0E 10-12 FUJI MACHINE MFG. CO., LTD
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineer
Proper Data Measurement
7. The following message displays when moving to the position for the B-holder Q-
axis measurement. Check that the Z-axis is at the upper end position, and then
press [OK].
8. Perform the proper data measurement in the same way for syringe B and the other
remaining syringes.
9.
Once the proper data measurement is complete for all the syringes,
select [Next] to begin the Z-axis proper data measurement.
Axis move! Z position OK?
OK
FK-9F50-08-0E 10-13 FUJI MACHINE MFG. CO., LTD
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineer
Proper Data Measurement
10.7 Z-axis Proper Data Measurement
1. Perform MT reset at the Z-axis upper end.
2. Set the Z-axis counter value to -19750, and then loosen the coupling and push the Z-
axis up/down lever cam follower lightly against the syringe arm (Top of the syringe
pusher). Then tighten the four coupling bolts equally. (Tightening torque wrench
0.4Nm).
(It is better to turn the servo ON or use the ABS to stop the Z-axis counter moving
during this measurement.)
3. The following screen displays after performing MT reset. Proceed to the upper limit
position measurement.
Evenly tighten 4
bolts. 0.4Nm
Cam follower
Arm