1_H24维修手册.pdf - 第140页
CONFIDENTIAL Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998 (C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8

C
C
h
h
a
a
p
p
t
t
e
e
r
r
1
1
1
1
C
C
a
a
m
m
e
e
r
r
a
a
p
p
o
o
s
s
i
i
t
t
i
i
o
o
n
n
a
a
d
d
j
j
u
u
s
s
t
t
m
m
e
e
n
n
t
t
,
,
c
c
u
u
r
r
r
r
e
e
n
n
t
t
v
v
a
a
l
l
u
u
e
e
(
(
g
g
r
r
a
a
y
y
s
s
c
c
a
a
l
l
e
e
v
v
a
a
l
l
u
u
e
e
)
)
a
a
d
d
j
j
u
u
s
s
t
t
m
m
e
e
n
n
t
t
a
a
n
n
d
d
a
a
r
r
e
e
a
a
c
c
h
h
e
e
c
c
k
k
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8

CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8

Edition 5.0 H24 Head Repair Training Text for Service Engineers
Camera position adjustment, current value (grayscale value) adjustment and area check
FK-9F50-08-0E 11-1 FUJI MACHINE MFG. CO., LTD.
Chapter 11 - Camera Position Adjustment, Current
Value (Grayscale Value) Adjustment and Area Check
11.1 Required Jigs
Head type Drawing No. Name Qty Photo
H24 (IPS2A) 2AGKNJ001500 H24 IPS camera
resolution
measurement jig
2
H24 2AGTHJ004800 IPS Monitor Jig 1
H24 H65297 Harness to connect to
the IPS monitor jig
1
Required software
Name Drawing No. Notes
MotionAdjustmentTool None Install from the NXT application CD-ROM
Inspection item Tolerance
LED current adjustment
Grayscale value GR = 120~160, GL =120~160 (adjust current
value so GR & GL gray scale values are greater than 95 & less
than 250. Target: 120
CURRENT value: 24 mA or less
Camera resolution
check
L: X = 92~108
L: Z = 92~108
Center value R: Xs = 380~400 (Target: 390), Zp = 235~255 (Target: 245)
L: Xp = 80~100 (Target: 90), Zp = 237~253 (Target: 245)
Tilt R: dX = 0~6 (Target: 0), dZ = 0~9 (Target: 0)
L: dX = 0~6 (Target: 0), dZ = 0~9 (Target: 0)