Edition 5.0 H24 Head Re pair T raining T ext for Ser v ice Enginee rs Camer a posi t ion adjus t ment, curr ent value (gr ays cale value ) a djustmen t a nd area ch ec k FK -9F50- 08-0E 1 1 -20 FU JI MACHINE MFG . CO., L…

Edition 5.0 H24 Head Repair Training Text for Service Engineers
Camera position adjustment, current value (grayscale value) adjustment and area check
FK-9F50-08-0E 11-19 FUJI MACHINE MFG. CO., LTD.
8. In the “ADJUSTMENT3 CHECK” screen block the right-hand glass with some paper and then
press the lower button to check the value is in the tolerance below. (In the example below the
right-hand glass as viewed from the front of the machine is blocked).
9. In the “ADJUSTMENT3 CHECK” screen block the left-hand glass with some paper and then
press the lower button to check the value is in the tolerance below. (In the example below the
left-hand glass as viewed from the front of the machine is blocked).
AREA2=NG AREA3=OK
S2=100% S3=0%
AREA2=OK AREA3=NG
S2=0% S3=100%
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8

Edition 5.0 H24 Head Repair Training Text for Service Engineers
Camera position adjustment, current value (grayscale value) adjustment and area check
FK-9F50-08-0E 11-20 FUJI MACHINE MFG. CO., LTD.
11.8 Adjusting the Nozzle Existence Current (Grayscale value)
1. Press the upper button to select “ADJUSTMENT 3 BACK” and then press the lower button to
change to “ADJUSTMENT 2 CURRENT”.
2. Press and hold the lower button to change to area 4 adjustment mode.
3. Press the lower button to display “CURRENT UP” or “CURRENT DOWN”, and then adjust the
current value.
4. Rotate the R-axis through one full rotation and confirm that there is no position where the
variation in the grayscale values (GT) is extreme. If the value is too big, check the fluorescent
status. If it is dirty, clean or replace it as necessary.
Tolerance Target
Grayscale values GT 160~180 180
CURRENT 24mA or less Same as tolerance
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8

Edition 5.0 H24 Head Repair Training Text for Service Engineers
Camera position adjustment, current value (grayscale value) adjustment and area check
FK-9F50-08-0E 11-21 FUJI MACHINE MFG. CO., LTD.
5. Press the upper button to display “CURRENT BACK”.
5. Press the lower button to return to “ADJUSTMENT 2 CURRENT”.
6. Press the upper button to display “ADJUSTMENT 2 SET” and then press the lower button to
save the settings.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8