Edition 5.0 H24 Head Repair Training Text for Service Engineers
Proper data measurement for H24 head using head bench
10. Hold the position, and then click [Register]. This is the holder A upper limit position.
The upper limit position is registered -250 pulses from this position. (For example, if
the measured value is -19,750 pulses, the value registered is -20,000 pulse).
11. Move the Z-axis lever to where it does not interfere with the syringe pusher. When
you click [OK], the lever moves to the next holder. Do NOT touch the head,because
the R-axis and Q-axis automatically rotate during this motion.
12. Measure holders B to X in the same way.
Move the Z-axis lever to
where it does not interfere
with the syringe pusher.
Z-axis lever
Syringe
FK-9F50-08-0E S1-17 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineers
Proper data measurement for H24 head using head bench
13. After measuring holder X, the following window opens. The lowest holder moves to
the front position when [OK] is clicked. Do NOT touch the head, the R-axis and Q-
axis automatically rotate during this motion.
14. Click [Next].
15. Move the Z-axis lever to where it does not interfere with the syringe pusher. The
lowest holder moves to the front position when [OK] is clicked. Do NOT touch the
head, because the R-axis and Q-axis automatically rotate during this motion.
Move the Z-axis lever to
where it does not interfere
with the syringe pusher.
Z-axis lever
Syringe
FK-9F50-08-0E S1-18 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineers
Proper data measurement for H24 head using head bench
16. Click [OK]. Next, measure the mechanical end.
17. Manually move the Z-axis to the upper limit mechanical end. Hold the position, and
then click [Register].
18. Manually move the Z-axis to the lower limit mechanical end. Hold the position, and
then click [Register]. .
19. Move the Z-axis lever to where it does not interfere with the syringe pusher.
Mechanical end measurement
Move the Z-axis lever to
where it does not interfere
with the syringe pusher.
Z-axis lever
Syringe
Mechanical end