Edition 5.0 H24 Head Repair Training Text for Service Engineers
Proper data measurement for H24 head using head bench
20. Click [Next].
21. Click [OK] to move holder A to the front. Do NOT touch the head, because the R-
axis and Q-axis automatically rotate during this motion.
22. This is the Z0 measurement window.
23. Remove the H24 head from the head bench and set it on a flat surface.
Note: Three cables are connected to the head. Please handle them carefully, to make
sure they are not disconnected.
Z0 measurement
Make sure that three
cables are connected.
Make sure that three
cables are connected.
FK-9F50-08-0E S1-20 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineers
Proper data measurement for H24 head using head bench
24. Attach the Z0 measurement master jig (AA1WA04) on the head bench. Place the
dial gauge indicator on the bottom surface of the jig. Set the dial to 0. (Set the dial
gauge stand near to the jig.)
25. Make sure that the dial gauge still reads “0. Remove the Z0 measurement master
jig (AA1WA04) from the head bench, and then attach the H24 head on the head
bench.
26. Attach the Z0 proper measurement jig (2AGKHJ015101) on holder A.
27. Lower the Z-axis by move” or manually to near by the dial gauge tip.
Note: Do NOT strongly push the dial gauge further more than one rotation. This will
change the Z0 position.
AA1WA0
FK-9F50-08-0E S1-21 FUJI MACHINE MFG. CO., LTD.
CONFIDENTIAL
Downloaded at 2015/06/18 12:05:48 (JST) by 5LUF0998
(C) FUJI Machine Mfg. Co., Ltd. All Rights Reserved. 2015/06/18 doc3elPkSB8
Edition 5.0 H24 Head Repair Training Text for Service Engineers
Proper data measurement for H24 head using head bench
28. Lower the Z-axis manually until the dial gauge reads 0”. Keep the position, and then
click Register to register the holder A Z0 position.
The holder A Z0 position is registered 2500 pulses below this position.
(For example, if the measured value is 16,000 pulses, the value registered is 18,500 pulses).
29. Move the Z-axis lever to where it does not interfere with the syringe pusher, and then
click [OK].
30. Measure holders B to X in the same way. Do NOT touch the head, because the R-
axis and Q-axis automatically rotate during this motion.
Move the Z-axis lever to
where it does not interfere
with the syringe pusher.
Z-axis lever
Syringe
16000
16000
16000
18500